Part Details | HYBRID RELAY
5945-01-184-8661 A self-contained device that performs the function of opening or closing an electrical circuit in response to electrical changes in an external circuit. It consists of a combination of semiconductor and passive circuit devices, which in turn control an integral electro-magnetic relay. Excludes relays which employ diodes, rectifiers or other passive devices to achieve contact protection or coil modification. Excludes RELAY, SOLID STATE.
Alternate Parts: M287761026P, M28776/1-026P, M287761026M, M28776/1-026M, MILR28776B, MIL-R-28776B, MILR287761, MIL-R-28776/1, MILPRF287761, MIL-PRF-28776/1, 5945-01-184-8661, 01-184-8661, 5945011848661, 011848661
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | JUL 24, 1984 | 01-184-8661 | 31445 ( RELAY, HYBRID ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 5945-01-184-8661
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| M28776/1-026P | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
| M28776/1-026M | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
| MIL-R-28776B | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
| MIL-R-28776/1 | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
| MIL-PRF-28776/1 | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
Technical Data | NSN 5945-01-184-8661
| Characteristic | Specifications |
|---|---|
| CONTACT ARRANGEMENT | DOUBLE POLE, DOUBLE THROW |
| FEATURES PROVIDED | TRANSISTOR DRIVEN AND HERMETICALLY SEALED |
| SPECIAL FEATURES | ELECTROMECHANICAL OUTPUT;TERMINAL MTD;CONTACT 1 AMP AT 28 VDC RESISTIVE;SUPPLY VOLTAGE 6VDC;COIL RESISTANCE 98 OHMS;WIRE LEAD TERMINALS;POLARIZED;WT 2.60 GRAMS;0.280 IN. LG;0.370 IN. DIA;TURN-ON TIME 2 MS MAX;TURN-OFF TIME 7.5 MS MAX;MODEARTELY RUGGED |
| SPECIFICATION/STANDARD DATA | 81349-MIL-R-28776 TO 1 GOVERNMENT SPECIFICATION |
| CRITICALITY CODE JUSTIFICATION | FEAT |