Part Details | ELECTROMAGNETIC RELAY
5945-01-218-7925 A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). Includes solenoid and armature types. Excludes CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; and SWITCH, STEPPING.
Alternate Parts: 84192009, 84192-009, 920710340, 9207-10340, B562, 1215448201, 1215448-201, 5945-01-218-7925, 01-218-7925, 5945012187925, 012187925
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | OCT 18, 1985 | 01-218-7925 | 32512 ( RELAY, ELECTROMAGNETIC ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 5945-01-218-7925
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 84192-009 | 16236 | DLA LAND AND MARITIMEDBA ENGINEERING AND TECHNICAL |
| 9207-10340 | 58657 | LEACH INTERNATIONAL CORPORATIONDBA ESTERLINE POWER SYSTEMS |
| B562 | 90536 | LOCKHEED MARTIN CORPORATIONDBA LOCKHEED MARTIN |
| 1215448-201 | D5440 | LOCKHEED MARTIN GMBH |
Technical Data | NSN 5945-01-218-7925
| Characteristic | Specifications |
|---|---|
| NONPILE-UP MAIN CONTACT ARRANGEMENT | 3 POLE, SINGLE THROW, NORMALLY OPEN, DOUBLE MAKE, MOMENTARY ACTION |
| NONPILE-UP AUXILIARY CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, NORMALLY OPEN, DOUBLE MAKE, MOMENTARY ACTION |
| MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 200.0 AC AND 28.0 DC |
| AUXILIARY CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND 28.0 DC |
| ARC QUENCHING METHOD | AIR |
| COIL QUANTITY | 1 |
| WINDING QUANTITY | 1 |
| DUTY TYPE | CONTINUOUS |
| ENVIRONMENTAL PROTECTION | HERMETIC |
| OVERALL LENGTH | 3.625 INCHES MAXIMUM |
| OVERALL WIDTH | 3.500 INCHES MAXIMUM |
| OVERALL HEIGHT | 2.843 INCHES MAXIMUM |
| PURPOSE FOR WHICH DESIGNED | GENERAL |
| CUBIC MEASURE | 36.071 CUBIC INCHES |
| FRAGILITY FACTOR | MODERATELY DELICATE |
| STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
| CASE MATERIAL | METAL |