Part Details | AUDIO FREQUENCY TRANSFORMER
5950-01-497-5567 A transformer which is designed so that part or all of its range of operating frequencies is 20 kilohertz (kilocycles) and below. The maximum value may extend into the radio frequency range. It is generally used in the input, output, amplifier, or oscillator stages of audio and sonar devices.
Alternate Parts: T235A3761, T235A376-1, 5950-01-497-5567, 01-497-5567, 5950014975567, 014975567
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | MAY 23, 2002 | 01-497-5567 | 00780 ( TRANSFORMER, AUDIO FREQUENCY ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 5950-01-497-5567
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| T235A376-1 | 78711 | TELEPHONICS CORPORATIONDBA COMMUNICATIONS SYSTEMS DIVISION |
Technical Data | NSN 5950-01-497-5567
| Characteristic | Specifications |
|---|---|
| TERMINAL TYPE AND QUANTITY | 7 WIRE LEAD |
| INCLOSURE TYPE | FULLY INCLOSED |
| BODY LENGTH | 0.500 INCHES MAXIMUM |
| BODY OUTSIDE DIAMETER | 0.350 INCHES MAXIMUM |
| RELIABILITY INDICATOR | NOT ESTABLISHED |
| SPECIAL FEATURES | PRIMARY DC RESISTANCE: 70 OHMS, SECONDARY: 1.5 OHMS; PRIMARY UNBALANCED DC CURRENT: 3.5 MA SINGLE ENDED USE MAX; POWER LEVEL: 600 MW AT 1KHZ; LEADS: 0.016 PORM .003 DIA. ELECTRO TIN PLATED EQUALLY SPACED AT 45 DEG ON A .20 DIA |
| MAXIMUM OPERATING TEMP | 105.0 DEG CELSIUS |
| END ITEM IDENTIFICATION | NSN:5895-01-233-2919, COMMUNICATION SYSTEM CONTROL GROUP |