Part Details | ELECTRON TUBE
5960-00-646-6303 An inclosure, including two or more electrodes, in which a flow of electrons may occur through a vacuum or a contained gas. The electronic conduction takes place either by means of electrons emitted from a cathode or by ionization of the contained gas. Includes phototubes (photoemissive type only), Geiger-Mueller tubes, traveling wave tubes, cathode ray tubes and microwave tubes (Klystron, magnetron, or the like). Excludes items whose primary purpose is to produce light energy. Also excludes PHOTOELECTRIC CELL; and SEMICONDUCTOR DEVICE (as modified).
Alternate Parts: DG732, DG7-32, 3AMP1, 1301DG732, 1301DG7-32, DG732, DG7-32, 5960-00-646-6303, 00-646-6303, 5960006466303, 006466303
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | JAN 01, 1963 | 00-646-6303 | 00001 ( ELECTRON TUBE ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 5960-00-646-6303
Part Number | Cage Code | Manufacturer |
---|---|---|
DG7-32 | K0577 | BRITISH SAROZAL LTD |
3AMP1 | 80131 | ELECTRONIC INDUSTRIES ASSOCIATION |
1301DG7-32 | S7218 | PLESSEY SOUTH AFRICA LTD |
DG7-32 | K0004 | VISHAY |
Technical Data | NSN 5960-00-646-6303
Characteristic | Specifications |
---|---|
TUBE TYPE | CATHODE RAY |
SPECIAL FEATURES | ENVELOPE MATERIAL: GLASS |
NONDEFINITIVE SPEC/STD DATA | 3AMP1 TYPE |