NSN 5961-01-252-8712

Part Details | TRANSISTOR

5961-01-252-8712 An active semiconductor device with three or more electrodes. May or may not include mounting hardware and/or heatsink. Excludes SEMICONDUCTOR DEVICE, DIODE and SEMICONDUCTOR DEVICE, THYRISTOR. For solid state devices which are responsive to visible or infrared radiant energy, see SEMICONDUCTOR DEVICE, PHOTO.

Alternate Parts: LO3705, 124800, 5961-01-252-8712, 01-252-8712, 5961012528712, 012528712

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59APR 09, 198701-252-871220588 ( TRANSISTOR )
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 5961-01-252-8712
Part Number Cage Code Manufacturer
LO370516236DLA LAND AND MARITIMEDBA ENGINEERING AND TECHNICAL
12480094271LOCKHEED MARTIN CORPORATIONDBA LOCKHEED MARTIN
Technical Data | NSN 5961-01-252-8712
Characteristic Specifications
SEMICONDUCTOR MATERIAL SILICON
INTERNAL CONFIGURATION FIELD EFFECT
VOLTAGE RATING IN VOLTS PER CHARACTERISTIC-100.0 MAXIMUM DRAIN TO GATE VOLTAGE AND -100.0 MAXIMUM DRAIN TO SOURCE VOLTAGE AND 20.0 MAXIMUM GATE TO SOURCE VOLTAGE
CURRENT RATING PER CHARACTERISTICCYM5.00 AMPERES MAXIMUM
POWER RATING PER CHARACTERISTICAG1.0 WATTS MAXIMUM
MAXIMUM OPERATING TEMP PER MEASUREMENT POINT150.0 DEG CELSIUS JUNCTION
INCLOSURE MATERIAL METAL
ELECTRODE INTERNALLY-ELECTRICALLY CONNECTED TO CASE COLLECTOR
JOINT ELECTRONIC DEVICE ENGINEERING COUNCIL/JEDEC/CASE OUTLINE DESIGNATIONTO-39
MOUNTING METHOD TERMINAL
TERMINAL LENGTH0.500 INCHES MINIMUM
TERMINAL CIRCLE DIAMETER0.210 INCHES MAXIMUM
TERMINAL TYPE AND QUANTITY3 UNINSULATED WIRE LEAD
OVERALL LENGTH0.260 INCHES MAXIMUM
OVERALL DIAMETER0.370 INCHES MAXIMUM
FEATURES PROVIDED HERMETICALLY SEALED CASE
SPECIAL FEATURESITEM MUST COMPLY WITH REQUIREMENTS OF DEFENSE SUPPLY CENTER COLUMBUS PRODUCTION STANDARD NO. LO3705
REFERENCE NUMBER DIFFERENTIATING CHARACTERISTICSREFERENCE NUMBER DIFFERENTIATING MATERIAL WILL BE IN ACCORDANCE WITH NAVAL INVENTORY CONTROL POINT ACTIVITY HX QUALITY CONTROL. MANUFACTURING AND TESTING SPECIFICATIONS AVAILABLE AT THE DLA ICP
CRITICALITY CODE JUSTIFICATIONZZZY