Part Details | SPECIAL PURPOSE ELECTRICAL INSULATION SLEEVING
5970-00-237-5662 A rigid or flexible tubing having other than uniform fabricated shapes or forms. It is specifically designed to prevent any undesirable flow of current between conductors or between conductors and other objects. Includes shrinkable type items. Excludes items not having rated electrical characteristics. Also excludes BUSHING, SLEEVE; CABLE NIPPLE, ELECTRICAL; and INSULATION SLEEVING, ELECTRICAL.
Alternate Parts: 430250011, 43025-0011, D30611, D-306-11, 10185983, 5970-00-237-5662, 00-237-5662, 5970002375662, 002375662
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | JAN 05, 1968 | 00-237-5662 | 61626 ( INSULATION SLEEVING, ELECTRICAL, SPECIAL PURPOSE ) |
REFERENCE DRAWINGS & PICTURES
BOOT-STRAIGHT

Cross Reference | NSN 5970-00-237-5662
Part Number | Cage Code | Manufacturer |
---|---|---|
43025-0011 | 27914 | HONEYWELL INTERNATIONAL INCDBA HONEYWELL |
D-306-11 | 06090 | TE CONNECTIVITY CORPORATIONDBA RAYCHEM PRODUCT DIVISION |
10185983 | 18876 | U S ARMY AVIATION AND MISSILECOMMAND |
Technical Data | NSN 5970-00-237-5662
Characteristic | Specifications |
---|---|
STYLE DESIGNATOR | BOOT-STRAIGHT |
MATERIAL | PLASTIC POLYVINYLIDENE FLUORIDE |
COLOR | CLEAR |
FLEXIBILITY | SEMIRIGID |
HEAT SHRINKAGE RATING IN PERCENT | 50.0 |
TEMP RATING | -55.0 DEG CELSIUS AND 175.0 DEG CELSIUS |
MINIMUM TENSILE STRENGTH | 5000 POUNDS PER SQUARE INCH |
DIELECTRIC MATERIAL VOLTAGE RATING PER UNIT THICKNESS | 800.0 VOLTS PER MIL /0.001 INCH/ |
ENVIRONMENTAL PROTECTION | CORROSION RESISTANT AND FLAME RESISTANT AND MILDEW RESISTANT AND WATER RESISTANT |
RELIABILITY INDICATOR | NOT ESTABLISHED |
SPECIAL FEATURES | SMALL END HAS LIP |