Part Details | STUFFING TUBE
5975-01-004-2006 An item specifically designed to pass an electrical cable or tube through a continuous structure with provisions for packing so as to prevent the leakage of liquids and/or gases through the opening. May include packing nut(s), adapter(s), washer(s), gasket(s), bushing(s), packing(s), cap(s), and/or plug(s).
Alternate Parts: G62628, GS872A5, 5975-01-004-2006, 01-004-2006, 5975010042006, 010042006
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | MAY 29, 1975 | 01-004-2006 | 00882 ( STUFFING TUBE ) |
REFERENCE DRAWINGS & PICTURES
SINGLE-EXTERNALLY THREADED
Cross Reference | NSN 5975-01-004-2006
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| G62628 | 06324 | GLENAIR, INC. |
| GS872A5 | 26512 | NORTHROP GRUMMAN SYSTEMS CORPORATIONDIV MISSION SYSTEMS |
Technical Data | NSN 5975-01-004-2006
| Characteristic | Specifications |
|---|---|
| STYLE DESIGNATOR | SINGLE-EXTERNALLY THREADED |
| OVERALL LENGTH | 1.250 INCHES NOMINAL |
| OVERALL HEIGHT | 1.750 INCHES NOMINAL |
| OVERALL WIDTH | 1.750 INCHES NOMINAL |
| MOUNTING HOLE DIAMETER | 0.169 INCHES NOMINAL |
| BORE DIAMETER | 1.156 INCHES NOMINAL |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING HOLES ALONG WIDTH | 1.370 INCHES NOMINAL |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING HOLES ALONG LENGTH | 1.370 INCHES NOMINAL |
| DISTANCE FROM MOUNTING HOLE CENTER TO BASE EDGE ALONG LENGTH | 0.190 INCHES NOMINAL |
| DISTANCE FROM MOUNTING HOLE CENTER TO BASE EDGE ALONG WIDTH | 0.190 INCHES NOMINAL |
| PACKING CHAMBER QUANTITY | 1 |
| MOUNTING METHOD | BOLT |
| FURNISHED ITEMS | GROMMET AND WASHER AND O-RING |
| SPECIAL FEATURES | ROMMET ANDWASHER HAVE 17 OPENINGS |