5985-00-236-7891 A specific electrical element or set of electrical elements that are connected together to form a fixed arrangement and used as a substitute load for terminating an electrical circuit. A dummy load contains all the essential electrical characteristics necessary to terminate the circuit but does not function in the same manner as the load which it replaces. Examples are resistors used to replace antennas, batteries, loudspeakers, or the like. Includes single port terminations of twin lead, coaxial and waveguide transmission lines as low power terminations of a section of a transmission system in a specified manner. Includes dummy loads when arranged in a group or bank. Excludes power absorbers. See also LOAD BANK, ELECTRICAL.

Alternate Parts: SMC570708, SM-C-570708, SMC570708, SM-C-570708, 5985-00-236-7891, 00-236-7891, 5985002367891, 002367891

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59MAR 12, 197100-236-789100335 ( DUMMY LOAD, ELECTRICAL )
REFERENCE DRAWINGS & PICTURES

WAVEGUIDE MOUNTED

Cross Reference | NSN 5985-00-236-7891
Part Number Cage Code Manufacturer
SM-C-57070891417HARRIS CORPORATIONDBA GOVERNMENT COMMUNICATIONS
SM-C-57070880063US ARMY COMMUNICATIONS &ELECTRONICS MATERIEL READINESS
Technical Data | NSN 5985-00-236-7891
Characteristic Specifications
STYLE DESIGNATOR WAVEGUIDE MOUNTED
OVERALL LENGTH3.500 INCHES NOMINAL
OVERALL HEIGHT1.937 INCHES NOMINAL
OVERALL WIDTH2.687 INCHES NOMINAL
BODY WIDTH1.750 INCHES NOMINAL
BODY HEIGHT1.125 INCHES NOMINAL
FREQUENCY RANGE RATING+5.850 TO +8.200 GIGAHERTZ
POWER RATING3.000 WATTS AVERAGE
TERMINATION TYPE WAVEGUIDE FLANGE
COOLING METHOD SELF-COOLED