Part Details | DIRECTIONAL COUPLER
5985-00-413-5386 An item specifically designed to be inserted into a transmission line, waveguide or coaxial transmission line to provide a suitable test outlet. The test signal is attenuated to a predetermined value.
Alternate Parts: 1351701, 135170-1, 5985-00-413-5386, 00-413-5386, 5985004135386, 004135386
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | MAY 06, 1970 | 00-413-5386 | 00384 ( COUPLER, DIRECTIONAL ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 5985-00-413-5386
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 135170-1 | 24930 | HARRIS CORPORATIONDBA ELECTRONIC SYSTEMS, RADAR |
Technical Data | NSN 5985-00-413-5386
| Characteristic | Specifications |
|---|---|
| UNIT TYPE | MM ANY ACCEPTABLE |
| RADIO FREQUENCY RATING | 2.9 GIGAHERTZ MINIMUM AND 3.1 GIGAHERTZ MAXIMUM |
| VOLTAGE STANDING WAVE RATIO AT REFERENCE FREQUENCY | NOT RATED |
| DESIGN TYPE | UNIDIRECTIONAL |
| POWER LOSS IN DECIBELS | 53.0 |
| TERMINAL FITTING NAME | FLANGE |
| TERMINAL FITTING CONTROLLING AGENCY | ITT GILFILLAN INC |
| TERMINAL FITTING IDENTIFYING NUMBER | PART NO. 144123-2 |
| TERMINAL FITTING USAGE DESIGN | WY ANY ACCEPTABLE |
| OVERALL LENGTH | 12.625 INCHES NOMINAL |
| OVERALL WIDTH | 12.375 INCHES NOMINAL |
| OVERALL HEIGHT | 4.625 INCHES NOMINAL |