Part Details | DIRECTIONAL COUPLER
5985-00-434-4280 An item specifically designed to be inserted into a transmission line, waveguide or coaxial transmission line to provide a suitable test outlet. The test signal is attenuated to a predetermined value.
Alternate Parts: 3A0056, 5985-00-434-4280, 00-434-4280, 5985004344280, 004344280
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | SEP 14, 1972 | 00-434-4280 | 00384 ( COUPLER, DIRECTIONAL ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 5985-00-434-4280
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 3A0056 | 31597 | ANAREN, INC. |
Technical Data | NSN 5985-00-434-4280
| Characteristic | Specifications |
|---|---|
| UNIT TYPE | MK ANY ACCEPTABLE |
| RADIO FREQUENCY RATING | 2.0 GIGAHERTZ MINIMUM AND 4.0 GIGAHERTZ MAXIMUM |
| DESIGN TYPE | UNIDIRECTIONAL |
| POWER LOSS IN DECIBELS | 20.0 |
| TERMINAL FITTING NAME | SMA FEMALE COUPLING |
| OVERALL LENGTH | 3.000 INCHES NOMINAL |
| OVERALL WIDTH | 2.950 INCHES NOMINAL |
| OVERALL HEIGHT | 0.500 INCHES NOMINAL |
| SPECIAL FEATURES | 50 OHNS IMPEDANCE; VSWR 1.50 MAX; POWER 100 W AVG AND 1 KW PEAK |
| PRECIOUS MATERIAL | GOLD |
| PRECIOUS MATERIAL AND LOCATION | CONTACT SURFACE GOLD |