NSN 5985-00-562-1287

Part Details | WAVEGUIDE ASSEMBLY

5985-00-562-1287 An item consisting of one or more definite lengths of straight or formed, flexible or rigid, prefabricated hollow tubing of conductive material. The tubing has a predetermined cross section and is designed to guide or conduct high frequency electromagnetic energy through its interior. One or more ends are terminated. May include common mounting of a SWITCH, WAVE GUIDE, a DUMMY LOAD, ELECTRICAL and other components such as waveguide section, cable terminal chamber and the like. Excludes COUPLER, ROTARY, RADIO FREQUENCY; COUPLER, DIRECTIONAL; ADAPTER, WAVEGUIDE; and TUNER, WAVEGUIDE.

Alternate Parts: 106092047, 106092-047, 2575959, 2575959, 5985-00-562-1287, 00-562-1287, 5985005621287, 005621287

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59NOV 17, 197400-562-128700305 ( WAVEGUIDE ASSEMBLY )
REFERENCE DRAWINGS & PICTURES

INTERNAL, RECTANGULAR EXTERNAL, RECTANGULAR

Cross Reference | NSN 5985-00-562-1287
Part Number Cage Code Manufacturer
106092-04780006LITTON SYSTEMS INCAIRTRON DIV
257595906351MICROWAVE ENGINEERING CORPORATION
257595910001NAVAIR AND NAVSEA MANAGEDORIGINAL DESIGN ACTIVITY DWG NOT
Technical Data | NSN 5985-00-562-1287
Characteristic Specifications
CROSS-SECTIONAL SHAPE STYLE INTERNAL, RECTANGULAR EXTERNAL, RECTANGULAR
WAVEGUIDE OUTSIDE WIDTH1.246 INCHES MINIMUM AND 1.254 INCHES MAXIMUM
WAVEGUIDE INSIDE WIDTH1.118 INCHES MINIMUM AND 1.126 INCHES MAXIMUM
WAVEGUIDE INSIDE HEIGHT0.493 INCHES MINIMUM AND 0.501 INCHES MAXIMUM
WAVEGUIDE OUTSIDE HEIGHT0.621 INCHES MINIMUM AND 0.629 INCHES MAXIMUM
FLANGE QUANTITY2
MAXIMUM OPERATING PRESSURE10.0 POUNDS PER SQUARE INCH GAGE
INSERTION LOSS IN DECIBELS0.25
VOLTAGE STANDING WAVE RATIO1.04
SPECIAL FEATURESA CRES FED-QQ-S766,CLASS 321,CONDITION A,2.312 IN. BEARING ON EACH FLANGE,RINGS HAVE EIGHT 0.1705 IN. DIA. HOLES-4 FOR MTG. TO FLANGE AND 4 FOR MTG. PURPOSES,ONE END ALSO HAS A 2.250 IN. LG. BY 2.000 IN. W. BRACKET WITH FOUR 0.1695 IN. DIA. HOLES EQUALLY SPACED ON 1.740 IN. BY 1.210 IN. MTG. CENTERS,BRACKET IS LOCATED 1.520 IN. FROM END OF FLANGE,TUBING WALL CONSTRUCTION CAN ALSO BE LAMINATED