NSN 5985-00-661-2263

Part Details | ELECTRICAL DUMMY LOAD

5985-00-661-2263 A specific electrical element or set of electrical elements that are connected together to form a fixed arrangement and used as a substitute load for terminating an electrical circuit. A dummy load contains all the essential electrical characteristics necessary to terminate the circuit but does not function in the same manner as the load which it replaces. Examples are resistors used to replace antennas, batteries, loudspeakers, or the like. Includes single port terminations of twin lead, coaxial and waveguide transmission lines as low power terminations of a section of a transmission system in a specified manner. Includes dummy loads when arranged in a group or bank. Excludes power absorbers. See also LOAD BANK, ELECTRICAL.

Alternate Parts: 890494, 890494, 1012187, 1857304, 5985-00-661-2263, 00-661-2263, 5985006612263, 006612263

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59JAN 01, 196300-661-226300335 ( DUMMY LOAD, ELECTRICAL )
REFERENCE DRAWINGS & PICTURES

WAVEGUIDE MOUNTED

Cross Reference | NSN 5985-00-661-2263
Part Number Cage Code Manufacturer
89049466544CONTINENTAL MICROWAVE AND TOOL CO.,INC.
89049480006LITTON SYSTEMS INCAIRTRON DIV
101218756232LOCKHEED MARTIN CORPORATIONDBA LOCKHEED MARTIN
185730410001NAVAIR AND NAVSEA MANAGEDORIGINAL DESIGN ACTIVITY DWG NOT
Technical Data | NSN 5985-00-661-2263
Characteristic Specifications
STYLE DESIGNATOR WAVEGUIDE MOUNTED
OVERALL LENGTH8.788 INCHES NOMINAL
OVERALL WIDTH4.426 INCHES NOMINAL
BODY WIDTH1.872 INCHES NOMINAL
BODY HEIGHT0.872 INCHES NOMINAL
OVERALL DIAMETER3.625 INCHES NOMINAL
FREQUENCY RANGE RATING+5.550 TO +5.750 GIGAHERTZ
POWER RATING150.000 KILOWATTS PEAK AND 150.000 WATTS AVERAGE
AMBIENT TEMP IN DEG CELSIUS AT FULL RATED POWER150.0
VOLTAGE STANDING WAVE RATIO1.05
VOLTAGE STANDING WAVE RATIO FREQUENCY RANGE+5.550 TO +5.750 GIGAHERTZ
TERMINATION TYPE WAVEGUIDE FLANGE
INTERNAL OPERATING PRESSURE12.0 POUNDS PER SQUARE INCH GAGE
WAVEGUIDE FLANGE DESIGNATIONUG407/U
COOLING METHOD SELF-COOLED
OPERATING POSITION HORIZONTAL