NSN 5985-01-106-7639

Part Details | VARIABLE ATTENUATOR

5985-01-106-7639 A device for reducing the strength of an alternating current signal either continuously or in steps, without causing appreciable signal distortion, by maintaining substantially constant output and/or input impedance match. Continuously variable resistive devices must consist of at least two sections or one section with at least two rotating contacts. The item must have an overall attenuation rating. Includes tandem mounted variable resistors designed to function as an attenuator but whose terminals are not connected. See also RESISTOR, VAIABLE (as modified).

Alternate Parts: 668470E, 6684-70E, C106172, C10617-2, 5985-01-106-7639, 01-106-7639, 5985011067639, 011067639

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59JAN 24, 198101-106-763900838 ( ATTENUATOR, VARIABLE )
REFERENCE DRAWINGS & PICTURES

COAXIAL TYPE

Cross Reference | NSN 5985-01-106-7639
Part Number Cage Code Manufacturer
6684-70E09992ARRA INC
C10617-281755LOCKHEED MARTIN CORPORATIONDBA LOCKHEED MARTIN AERONAUTICS
Technical Data | NSN 5985-01-106-7639
Characteristic Specifications
APPLICATION DESIGN TRANSMISSION LINE
FREQUENCY RANGE7.000 GIGAHERTZ MINIMUM AND 12.400 GIGAHERTZ MAXIMUM
IMPEDANCE RATING IN OHMS50.0 INPUT-OUTPUT
VOLTAGE STANDING WAVE RATIO1.50
POWER RATING10.0 WATTS AVERAGE AND 5.0 KILOWATTS PEAK
INSERTION LOSS AT MINIMUM ATTENUATION IN MAXIMUM DECIBELS1.0
OVERALL ATTENUATION RANGE IN DECIBELSP0.0/P70.0
ATTENUATION VARIATION METHOD CONTINUOUS
BODY STYLE COAXIAL TYPE
OVERALL LENGTH4.440 INCHES MAXIMUM
OVERALL HEIGHT3.000 INCHES NOMINAL
OVERALL WIDTH3.850 INCHES NOMINAL
ADJUSTMENT DEVICE TYPE AND QUANTITY1 KNOB
TERMINAL TYPE AND QUANTITY2 CONNECTOR, COAXIAL, FEMALE
COAXIAL CONNECTOR SERIES DESIGNATION SMA
MOUNTING FACILITY TYPE AND QUANTITY4 THREADED HOLE
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATOR UNC
MOUNTING FACILITY NOMINAL SCREW THREAD DIAMETER0.164 INCHES
MOUNTING THREAD QUANTITY32 PER INCH
MOUNTING FACILITY PATTERN FOUR POSITION RECTANGULAR
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH2.000 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH2.000 INCHES NOMINAL
OPERATING TEMP RANGE+0.0 TO +65.0 DEG CELSIUS