NSN 5985-01-140-1559

Part Details | FIXED ATTENUATOR

5985-01-140-1559 A device for reducing the strength of an alternating current signal by a fixed or predetermined amount, without causing appreciable signal distortion, by maintaining correct impedance match.

Alternate Parts: 769A20, 769A-20, 76920, 769-20, 5985-01-140-1559, 01-140-1559, 5985011401559, 011401559

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59OCT 08, 198201-140-155914224 ( ATTENUATOR, FIXED )
REFERENCE DRAWINGS & PICTURES

RECTANGULAR, TERMINAL/TERMINALS ON OPPOSITE SURFACES

Cross Reference | NSN 5985-01-140-1559
Part Number Cage Code Manufacturer
769A-2099899L3 TECHNOLOGIES, INC.DBA NARDA MICROWAVE EAST
769-2099899L3 TECHNOLOGIES, INC.DBA NARDA MICROWAVE EAST
Technical Data | NSN 5985-01-140-1559
Characteristic Specifications
APPLICATION DESIGN TRANSMISSION LINE
FREQUENCY RANGE0.000 HERTZ MINIMUM AND 6.000 GIGAHERTZ MAXIMUM
VOLTAGE STANDING WAVE RATIO1.35
VOLTAGE STANDING WAVE RATIO FREQUENCY RANGE+0.0 TO +6.0 GIGAHERTZ
RF SIGNAL ATTENUATION IN DECIBELS20.0
ATTENUATION ACCURACY IN DECIBELSM0.75/P0.75
POWER RATING150.0 WATTS AVERAGE AND 3.0 KILOWATTS PEAK
BODY STYLE RECTANGULAR, TERMINAL/TERMINALS ON OPPOSITE SURFACES
OVERALL LENGTH7.281 INCHES NOMINAL
OVERALL HEIGHT4.500 INCHES NOMINAL
OVERALL WIDTH4.000 INCHES NOMINAL
TERMINAL TYPE AND QUANTITY2 CONNECTOR
COAXIAL CONNECTOR SERIES DESIGNATION N
CONNECTION TYPE PER FUNCTION MALE INPUT AND FEMALE OUTPUT
MOUNTING METHOD UNTHREADED HOLE
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH6.156 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH3.000 INCHES NOMINAL