Part Details | ALTERNATING CURRENT MOTOR
6105-00-449-5301 A motor which is designed for operation from an alternating current source. See also MOTOR, CONTROL.
Alternate Parts: 5XBG015D, 5XBG015D, 5XBG015, S4305, 6105-00-449-5301, 00-449-5301, 6105004495301, 004495301
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 61 | MAY 30, 1974 | 00-449-5301 | 00530 ( MOTOR, ALTERNATING CURRENT ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6105-00-449-5301
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 5XBG015D | 03511 | GENERAL ELECTRIC COSPECIALTY MOTOR DEPT |
| 5XBG015D | 38151 | MARATHON ELECTRIC MANUFACTURINGCORPORATION |
| 5XBG015 | 28891 | UNITED TECHNOLOGIES-ESSEX/IWI DIV |
| S4305 | 28891 | UNITED TECHNOLOGIES-ESSEX/IWI DIV |
Technical Data | NSN 6105-00-449-5301
| Characteristic | Specifications |
|---|---|
| OVERALL LENGTH | 8.270 INCHES |
| OVERALL WIDTH | 5.620 INCHES |
| OVERALL HEIGHT | 5.830 INCHES |
| MOUNTING METHOD | FIXED BASE |
| MOUNTING FACILITY TYPE AND QUANTITY | 4 SLOT |
| NOMINAL CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.760 INCHES |
| NOMINAL CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 4.250 INCHES |
| INCLOSURE FEATURE | DRIPPROOF PROTECTED-15 DEG |
| INCLOSURE SPECIFICATION | NEMA |
| FRAME SIZE DESIGNATION | 48 |
| CURRENT RATING METHOD | LOAD |
| WINDING TYPE | INDUCTION-SINGLE VALUE CAPACITOR SPLIT PHASE |
| DUTY CYCLE | CONTINUOUS |
| TEMP RATING | 40.0 AMBIENT DEG CELSIUS |
| COOLING METHOD | NATURAL CONVECTION VENTILATED |
| ROTOR SPEED RATING IN RPM | 1725.0 SINGLE FULL LOAD |
| FEATURES PROVIDED | THERMAL PROTECTIVE DEVICE AND HORIZONTAL MOUNTING POSITION |
| SPECIFIC USE | BLOWER ASSY STEWART WARNER AIRCONDITIONER MODEL NO. RC-A-P-2 |