Part Details | DIRECT CURRENT MOTOR
6105-00-500-1239 A motor which is designed for operation from a direct current source. Excludes MOTOR, ENGINE STARTER, ELECTRICAL. See also MOTOR, CONTROL.
Alternate Parts: D59737, D5-973-7, D59737, D5-973-7, 6105-00-500-1239, 00-500-1239, 6105005001239, 005001239
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 61 | JAN 01, 1963 | 00-500-1239 | 16350 ( MOTOR, DIRECT CURRENT ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6105-00-500-1239
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| D5-973-7 | 95402 | ELECTRIC BOAT CORPDBA ELECTRO DYNAMIC |
| D5-973-7 | 96169 | ELECTRIC BOAT CORPORATION |
Technical Data | NSN 6105-00-500-1239
| Characteristic | Specifications |
|---|---|
| OVERALL LENGTH | 31.500 INCHES |
| OVERALL WIDTH | 25.562 INCHES |
| OVERALL HEIGHT | 25.500 INCHES |
| MOUNTING METHOD | FIXED BASE |
| MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE |
| NOMINAL CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 10.750 INCHES |
| NOMINAL CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 15.500 INCHES |
| INCLOSURE FEATURE | DRIPPROOF-15 DEG |
| INCLOSURE SPECIFICATION | MIL-STD-108 |
| CURRENT RATING METHOD | LOAD |
| WINDING TYPE | COMPOUND WOUND |
| DUTY CYCLE | CONTINUOUS |
| TEMP RATING | 40.0 AMBIENT DEG CELSIUS AND 50.0 OPERATING DEG CELSIUS |
| COOLING METHOD | SELF-VENTILATED |
| FEATURES PROVIDED | VERTICAL MOUNTING POSITION |