Part Details | DIRECT CURRENT MOTOR
6105-00-521-6852 A motor which is designed for operation from a direct current source. Excludes MOTOR, ENGINE STARTER, ELECTRICAL. See also MOTOR, CONTROL.
Alternate Parts: 091953, 091953, 091953, 6105-00-521-6852, 00-521-6852, 6105005216852, 005216852
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 61 | JAN 01, 1963 | 00-521-6852 | 16350 ( MOTOR, DIRECT CURRENT ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6105-00-521-6852
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 091953 | 06650 | BELL AND HOWELL PHILLIPSBURG COCORPORATE OFFICES |
| 091953 | 26581 | HAMILTON SUNDSTRAND CORPORATIONDBA APPLIED SCIENCE OPERATION |
| 091953 | 07694 | TRIAD CORP |
Technical Data | NSN 6105-00-521-6852
| Characteristic | Specifications |
|---|---|
| OVERALL LENGTH | 1.750 INCHES |
| OVERALL WIDTH | 1.000 INCHES |
| OVERALL HEIGHT | 0.750 INCHES |
| MOUNTING METHOD | FIXED BASE |
| MOUNTING FACILITY TYPE AND QUANTITY | 2 UNTHREADED HOLE |
| NOMINAL CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 0.781 INCHES |
| NOMINAL CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 0.781 INCHES |
| INCLOSURE FEATURE | TOTALLY INCLOSED |
| CURRENT RATING METHOD | LOAD |
| WINDING TYPE | PERMANENT MAGNET |
| DUTY CYCLE | INTERMITTENT |
| TIME INTERVAL | 1.0 MINUTES MAXIMUM ON AND 1.0 MINUTES MINIMUM OFF |
| TEMP RATING | -65.0 OPERATING DEG CELSIUS AND 70.0 OPERATING DEG CELSIUS |
| MAXIMUM OPERATING ALTITUDE RATING | 50000.0 FEET |
| TERMINAL TYPE AND QUANTITY | 2 WIRE LEAD |
| ROTOR SPEED RATING IN RPM | 10000.0 SINGLE FULL LOAD |