Part Details | DIRECT CURRENT MOTOR
6105-00-548-2041 A motor which is designed for operation from a direct current source. Excludes MOTOR, ENGINE STARTER, ELECTRICAL. See also MOTOR, CONTROL.
Alternate Parts: MILM17413SERVICEA, 1JD863, S1775905, S013B4406, 1JD863, 6105-00-548-2041, 00-548-2041, 6105005482041, 005482041
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 61 | JAN 01, 1963 | 00-548-2041 | 16350 ( MOTOR, DIRECT CURRENT ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6105-00-548-2041
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| MILM17413SERVICEA | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
| 1JD863 | 79500 | WESTINGHOUSE ELECTRIC CORP |
| S1775905 | 79500 | WESTINGHOUSE ELECTRIC CORP |
| S013B4406 | 79500 | WESTINGHOUSE ELECTRIC CORP |
| 1JD863 | 11660 | WESTINGHOUSE ELECTRIC CORPCONTROL BUSINESS UNIT |
Technical Data | NSN 6105-00-548-2041
| Characteristic | Specifications |
|---|---|
| OVERALL LENGTH | 35.813 INCHES |
| OVERALL WIDTH | 23.000 INCHES |
| OVERALL HEIGHT | 26.063 INCHES |
| MOUNTING METHOD | FIXED BASE |
| MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE |
| NOMINAL CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 12.250 INCHES |
| NOMINAL CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 19.250 INCHES |
| INCLOSURE FEATURE | DRIPPROOF-15 DEG |
| INCLOSURE SPECIFICATION | MIL-STD-108 |
| FRAME SIZE DESIGNATION | 83 |
| CURRENT RATING METHOD | LOAD |
| WINDING TYPE | COMPOUND WOUND |
| DUTY CYCLE | CONTINUOUS |
| TEMP RATING | 40.0 AMBIENT DEG CELSIUS AND 50.0 OPERATING DEG CELSIUS |
| COOLING METHOD | SELF-VENTILATED |
| TERMINAL TYPE AND QUANTITY | 6 SOLDER LUG |
| ROTOR SPEED RATING IN RPM | 850.0 SINGLE FULL LOAD |
| FEATURES PROVIDED | HORIZONTAL MOUNTING POSITION |