Part Details | ALTERNATING CURRENT MOTOR
6105-00-906-0637 A motor which is designed for operation from an alternating current source. See also MOTOR, CONTROL.
Alternate Parts: 699A240, A1088475G61, 6105-00-906-0637, 00-906-0637, 6105009060637, 009060637
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 61 | JUN 15, 1966 | 00-906-0637 | 00530 ( MOTOR, ALTERNATING CURRENT ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6105-00-906-0637
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 699A240 | 30552 | GENERAL ELECTRIC CODISTRIBUTION TRANSFORMER BUSINESS |
| A1088475G61 | 28527 | HARRIS CORPORATIONDBA ELECTRONIC SYSTEMS, INTEGRATED |
Technical Data | NSN 6105-00-906-0637
| Characteristic | Specifications |
|---|---|
| OVERALL LENGTH | 7.594 INCHES |
| OVERALL WIDTH | 8.062 INCHES |
| OVERALL HEIGHT | 6.875 INCHES |
| MOUNTING METHOD | RESILIENT CRADLE |
| MOUNTING FACILITY TYPE AND QUANTITY | 2 CLAMP COLLAR |
| NOMINAL CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 3.000 INCHES |
| NOMINAL CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 4.125 INCHES |
| INCLOSURE FEATURE | TOTALLY INCLOSED |
| INCLOSURE SPECIFICATION | COMMERCIAL |
| CURRENT RATING METHOD | LOAD |
| TORQUE RATING AND TYPE | 2.63 INCH-OUNCES RUNNING |
| WINDING TYPE | SYNCHRONOUS |
| DUTY CYCLE | CONTINUOUS |
| COOLING METHOD | AMBIENT AIR |
| TERMINAL TYPE AND QUANTITY | 3 WIRE LEAD |
| ROTOR SPEED RATING IN RPM | 1600.0 SINGLE FULL LOAD |
| FEATURES PROVIDED | HORIZONTAL MOUNTING POSITION |