Part Details | MOTOR-TACHOMETER GENERATOR
6105-00-941-6096 An item which is an electrical rotating machine combining both control motor and tachometer generator action. The control motor and tachometer generator may be contained in the same or separate housings. It is designed for servo application where instant response to input signal is essential. It is generally used in circuits where the output potential from the tachometer generator is fed back to prevent excessive oscillation and for assuring high stability in a servo loop. Excludes DYNAMOTOR; and MOTOR-GENERATOR.
Alternate Parts: FD84681, FD84-68-1, 763677, 77C707820P1, 6105-00-941-6096, 00-941-6096, 6105009416096, 009416096
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 61 | DEC 03, 1965 | 00-941-6096 | 28454 ( MOTOR-TACHOMETER GENERATOR ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6105-00-941-6096
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| FD84-68-1 | 88818 | KEARFOTT CORPORATIONDBA KEARFOTT |
| 763677 | A2309 | LEONARDO SPA DIVISIONE SISTEMI DIDIFESA |
| 77C707820P1 | 03538 | LOCKHEED MARTIN CORPORATIONDIV RMS |
Technical Data | NSN 6105-00-941-6096
| Characteristic | Specifications |
|---|---|
| OVERALL LENGTH | 9.969 INCHES |
| OVERALL WIDTH | 4.312 INCHES |
| MOUNTING METHOD | CLAMP RING |
| TORQUE RATING AND TYPE | 13.0 FOOT-OUNCES RUNNING AND 32.0 FOOT-OUNCES STALLED |
| TEMP RATING | -55.0 OPERATING DEG CELSIUS AND 65.0 OPERATING DEG CELSIUS |
| MAXIMUM OPERATING ALTITUDE RATING | 10000.0 FEET |
| CALIBRATION VOLTAGE OUTPUT TYPE IN VOLTS | 15.5 DC |
| CALIBRATION SPEED IN RPM | 1000.0 |
| CONTROL FIELD VOLTAGE TYPE AND RATING IN VOLTS | 100.0 DC |
| ROTOR SPEED RATING IN RPM | 4000.0 SINGLE FULL LOAD |
| FEATURES PROVIDED | VERTICAL MOUNTING POSITION AND HORIZONTAL MOUNTING POSITION |