Part Details | CONTROL MOTOR
6105-00-964-1227 A motor which is designed to be operated from two independent voltage sources, in such a way that variations in one voltage source will determine the direction and speed of the motor. In the alternating current type the voltages are usually applied to a split-phase stator, whereas in the direct current type, one voltage is applied to the stator and the other to the armature. Low inertia and rapid reversibility are inherent characteristics of this type of motor. See also SERVOMOTOR, AUTOMATIC PILOT.
Alternate Parts: 15IM461, 103489, 6105-00-964-1227, 00-964-1227, 6105009641227, 009641227
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 61 | JAN 01, 1962 | 00-964-1227 | 19258 ( MOTOR, CONTROL ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6105-00-964-1227
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 15IM461 | 80740 | BECKMAN COULTER, INC.DIV US CUSTOMER OPERATIONS |
| 103489 | 24930 | HARRIS CORPORATIONDBA ELECTRONIC SYSTEMS, RADAR |
Technical Data | NSN 6105-00-964-1227
| Characteristic | Specifications |
|---|---|
| OVERALL LENGTH | 2.989 INCHES |
| OVERALL WIDTH | 1.437 INCHES |
| OVERALL HEIGHT | 1.437 INCHES |
| MOUNTING METHOD | END BELL |
| MOUNTING FACILITY TYPE AND QUANTITY | 4 THREADED HOLE |
| MOUNTING FACILITY CIRCLE DIAMETER | 1.100 INCHES |
| INCLOSURE SPECIFICATION | COMMERCIAL |
| CURRENT RATING METHOD | NO LOAD |
| TEMP RATING | -55.0 OPERATING DEG CELSIUS AND 125.0 OPERATING DEG CELSIUS |
| CONTROL FIELD VOLTAGE TYPE AND RATING IN VOLTS | 20.0 AC AND 40.0 AC |
| CONTROL FIELD CURRENT RATING IN AMPS | B0.425$$B0.850 |
| CONTROL FIELD WINDING TYPE | Y$X |
| ROTOR SPEED RATING IN RPM | 6000.0 SINGLE NO LOAD |
| FEATURES PROVIDED | HORIZONTAL MOUNTING POSITION AND VERTICAL MOUNTING POSITION |