Part Details | ALTERNATING CURRENT MOTOR
6105-00-980-2695 A motor which is designed for operation from an alternating current source. See also MOTOR, CONTROL.
Alternate Parts: 5KSP29BG3002T, 5KSP29BG3002BT, 2332, 7530030A, 75-30-030A, 6105-00-980-2695, 00-980-2695, 6105009802695, 009802695
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 61 | JAN 01, 1962 | 00-980-2695 | 00530 ( MOTOR, ALTERNATING CURRENT ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6105-00-980-2695
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 5KSP29BG3002T | 03510 | GENERAL ELECTRIC COMOTOR BUSINESS GROUP |
| 5KSP29BG3002BT | 03510 | GENERAL ELECTRIC COMOTOR BUSINESS GROUP |
| 2332 | 03510 | GENERAL ELECTRIC COMOTOR BUSINESS GROUP |
| 75-30-030A | 30190 | ILG INDUSTRIES INC |
Technical Data | NSN 6105-00-980-2695
| Characteristic | Specifications |
|---|---|
| OVERALL LENGTH | 7.050 INCHES |
| OVERALL WIDTH | 5.010 INCHES |
| OVERALL HEIGHT | 5.010 INCHES |
| MOUNTING METHOD | FACE AND RESILIENT RING |
| MOUNTING FACILITY TYPE AND QUANTITY | 4 THREADED HOLE |
| MOUNTING FACILITY CIRCLE DIAMETER | 3.500 INCHES |
| INCLOSURE FEATURE | OPEN PROTECTED |
| INCLOSURE SPECIFICATION | COMMERCIAL |
| CURRENT RATING METHOD | LOAD |
| WINDING TYPE | INDUCTION-SHADED POLE |
| DUTY CYCLE | CONTINUOUS |
| TEMP RATING | 40.0 OPERATING DEG CELSIUS AND 50.0 AMBIENT DEG CELSIUS |
| COOLING METHOD | SELF-VENTILATED |
| TERMINAL TYPE AND QUANTITY | 2 WIRE LEAD |
| ROTOR SPEED RATING IN RPM | 1550.0 SINGLE FULL LOAD |
| FEATURES PROVIDED | THERMAL PROTECTIVE DEVICE AND HORIZONTAL MOUNTING POSITION AND VERTICAL MOUNTING POSITION |
| BEARING TYPE | SLEEVE |