Part Details | ALTERNATING CURRENT MOTOR
6105-01-146-1391 A motor which is designed for operation from an alternating current source. See also MOTOR, CONTROL.
Alternate Parts: M3107M4FM28A, M3107-M4FM28A, 341795157, 34-1795-157, M3107M4FM28A, M3107-M4FM28A, 341795157, 34-1795-157, PT396001, PT396-001, 6105-01-146-1391, 01-146-1391, 6105011461391, 011461391
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 61 | JAN 25, 1983 | 01-146-1391 | 00530 ( MOTOR, ALTERNATING CURRENT ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6105-01-146-1391
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| M3107-M4FM28A | 05472 | BALDOR ELECTRIC CO |
| 34-1795-157 | 05472 | BALDOR ELECTRIC CO |
| M3107-M4FM28A | 46UR5 | BALDOR ELECTRIC COMPANYDBA BALDOR MOTORS AND DRIVE |
| 34-1795-157 | 46UR5 | BALDOR ELECTRIC COMPANYDBA BALDOR MOTORS AND DRIVE |
| PT396-001 | 32332 | JOHNSTON BOILER COMPANY |
Technical Data | NSN 6105-01-146-1391
| Characteristic | Specifications |
|---|---|
| OVERALL LENGTH | 10.250 INCHES |
| OVERALL WIDTH | 7.344 INCHES |
| OVERALL HEIGHT | 6.375 INCHES |
| MOUNTING METHOD | FIXED BASE |
| MOUNTING FACILITY TYPE AND QUANTITY | 4 SLOT |
| NOMINAL CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 3.000 INCHES |
| NOMINAL CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 5.125 INCHES |
| INCLOSURE FEATURE | OPEN AND WEATHERPROOF |
| INCLOSURE SPECIFICATION | NEMA |
| FRAME SIZE DESIGNATION | 56 |
| CURRENT RATING METHOD | LOAD |
| WINDING TYPE | INDUCTION-SHADED POLE |
| DUTY CYCLE | CONTINUOUS |
| TEMP RATING | 50.0 OPERATING DEG CELSIUS |
| COOLING METHOD | SELF-VENTILATED |
| TERMINAL TYPE AND QUANTITY | 9 WIRE LEAD |
| ROTOR SPEED RATING IN RPM | 3450.0 SINGLE NO LOAD |
| FEATURES PROVIDED | HORIZONTAL MOUNTING POSITION |