Part Details | ALTERNATING CURRENT MOTOR
6105-01-164-3712 A motor which is designed for operation from an alternating current source. See also MOTOR, CONTROL.
Alternate Parts: 2131, 3M471, 6105-01-164-3712, 01-164-3712, 6105011643712, 011643712
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 61 | OCT 15, 1983 | 01-164-3712 | 00530 ( MOTOR, ALTERNATING CURRENT ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6105-01-164-3712
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 2131 | 88422 | GENERAL ELECTRIC COMOTOR BUSINESS GROUP |
| 3M471 | 25795 | W.W. GRAINGER, INC.DBA GRAINGER |
Technical Data | NSN 6105-01-164-3712
| Characteristic | Specifications |
|---|---|
| OVERALL LENGTH | 7.500 INCHES |
| OVERALL WIDTH | 5.625 INCHES |
| OVERALL HEIGHT | 5.625 INCHES |
| MOUNTING METHOD | FACE |
| MOUNTING FACILITY TYPE AND QUANTITY | 4 THREADED HOLE |
| MOUNTING FACILITY CIRCLE DIAMETER | 2.474 INCHES |
| INCLOSURE FEATURE | OPEN PROTECTED |
| INCLOSURE SPECIFICATION | NEMA |
| FRAME SIZE DESIGNATION | 21 |
| CURRENT RATING METHOD | LOAD |
| WINDING TYPE | INDUCTION-SHADED POLE |
| DUTY CYCLE | CONTINUOUS |
| TEMP RATING | 40.0 AMBIENT DEG CELSIUS |
| COOLING METHOD | AMBIENT AIR |
| TERMINAL TYPE AND QUANTITY | 2 WIRE LEAD |
| ROTOR SPEED RATING IN RPM | 1550.0 SINGLE FULL LOAD |
| FEATURES PROVIDED | THERMAL PROTECTIVE DEVICE AND HORIZONTAL MOUNTING POSITION AND VERTICAL MOUNTING POSITION |