Part Details | ALTERNATING CURRENT MOTOR
6105-01-234-6611 A motor which is designed for operation from an alternating current source. See also MOTOR, CONTROL.
Alternate Parts: 6K149, P48S34S248, EL2002, 6K149, 6105-01-234-6611, 01-234-6611, 6105012346611, 012346611
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 61 | JUN 18, 1986 | 01-234-6611 | 00530 ( MOTOR, ALTERNATING CURRENT ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6105-01-234-6611
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 6K149 | 7D665 | GRAINGER DIV OF W W GRAINGER INC |
| P48S34S248 | 38151 | MARATHON ELECTRIC MANUFACTURINGCORPORATION |
| EL2002 | 05147 | SMITH A O CORPELECTRIC MOTORS DIV |
| 6K149 | 25795 | W.W. GRAINGER, INC.DBA GRAINGER |
Technical Data | NSN 6105-01-234-6611
| Characteristic | Specifications |
|---|---|
| OVERALL LENGTH | 9.250 INCHES |
| OVERALL WIDTH | 5.250 INCHES |
| OVERALL HEIGHT | 5.875 INCHES |
| MOUNTING METHOD | FLANGE |
| MOUNTING FACILITY TYPE AND QUANTITY | 4 SLOT |
| NOMINAL CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.750 INCHES |
| NOMINAL CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 4.250 INCHES |
| INCLOSURE FEATURE | TOTALLY INCLOSED |
| INCLOSURE SPECIFICATION | NEMA |
| FRAME SIZE DESIGNATION | 48N |
| CURRENT RATING METHOD | LOAD |
| WINDING TYPE | INDUCTION-SPLIT PHASE |
| DUTY CYCLE | CONTINUOUS |
| TEMP RATING | 40.0 AMBIENT DEG CELSIUS |
| COOLING METHOD | AMBIENT AIR |
| TERMINAL TYPE AND QUANTITY | 2 WIRE LEAD |
| ROTOR SPEED RATING IN RPM | 3450.0 SINGLE NO LOAD |
| FEATURES PROVIDED | THERMAL PROTECTIVE DEVICE |