Part Details | DIESEL ENGINE GENERATOR SET
6115-00-116-2216 A generator set using a diesel engine as the prime mover. Excludes GENERATOR SET, DIESEL ENGINE, TRAILER MOUNTED.
Alternate Parts: EMU20U, 01301000, 0130-1000, MILG38441, 67D40549, 6115-00-116-2216, 00-116-2216, 6115001162216, 001162216
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 61 | OCT 04, 1968 | 00-116-2216 | 00476 ( GENERATOR SET, DIESEL ENGINE ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6115-00-116-2216
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| EMU20U | 80049 | DEPARTMENT OF THE AIR FORCE |
| 0130-1000 | 93742 | DRS CONSOLIDATED CONTROLS, INC. |
| MILG38441 | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
| 67D40549 | 98749 | SACRAMENTO AIR LOGISTICS CENTERSM-ALC/LIIL |
Technical Data | NSN 6115-00-116-2216
| Characteristic | Specifications |
|---|---|
| CURRENT TYPE | AC |
| AC WATTAGE RATING | 15.0 KILOWATTS |
| FREQUENCY RATING | 400.0 HERTZ NOMINAL |
| PHASE | THREE |
| LINE TO LINE VOLTAGE IN VOLTS | 208.0 |
| LINE TO NEUTRAL VOLTAGE IN VOLTS | 120.0 |
| POWER FACTOR IN PERCENT | 0.8 |
| EXCITOR TYPE | SEPARATELY EXCITED |
| EXCITOR | INCLUDED |
| AMBIENT TEMP IN DEG CELSIUS | 50.0 |
| TEMP RISE RATING IN DEG CELSIUS FOR CONTINUOUS OPERATION | 75.0 |
| MANUFACTURER NAME | ELECTRIC MACHINERY MFG CO |
| PRIME MOVER COOLING MEDIUM | LIQUID |
| COOLING METHOD | RADIATOR |
| PRIME MOVER STARTING METHOD | C ANY ACCEPTABLE |
| CRANKING VOLTAGE IN VOLTS | 24.0 |
| AUTOMATIC STARTING FEATURE | PROVIDED |
| PRIME MOVER MANUFACTURER NAME | HERCULES ENGINES,INC |
| MOUNTING TYPE | SKID |
| OVERALL LENGTH | 74.000 INCHES NOMINAL |
| OVERALL WIDTH | 36.000 INCHES NOMINAL |
| OVERALL HEIGHT | 60.000 INCHES NOMINAL |
| RADIO INTERFERENCE SUPPRESSION | INCLUDED |
| WINTERIZATION FEATURE | INCLUDED |
| HOUSING TYPE | INCLOSED |
| INCLOSURE TYPE | FULLY INCLOSED |