Part Details | GASOLINE ENGINE GENERATOR SET
6115-00-329-3606 A generator set using a gasoline engine as the prime mover. Excludes GENERATOR SET, GASOLINE ENGINE, TRAILER MOUNTED.
Alternate Parts: C26B, MILG6343, 6115-00-329-3606, 00-329-3606, 6115003293606, 003293606
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 61 | JAN 01, 1963 | 00-329-3606 | 00477 ( GENERATOR SET, GASOLINE ENGINE ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6115-00-329-3606
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| C26B | 80049 | DEPARTMENT OF THE AIR FORCE |
| MILG6343 | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
Technical Data | NSN 6115-00-329-3606
| Characteristic | Specifications |
|---|---|
| PRIME MOVER COOLING MEDIUM | AIR |
| MOUNTING TYPE | WHEEL |
| OVERALL LENGTH | 96.000 INCHES NOMINAL |
| OVERALL WIDTH | 50.000 INCHES NOMINAL |
| OVERALL HEIGHT | 50.000 INCHES NOMINAL |
| CURRENT TYPE | AC |
| AMBIENT TEMP IN DEG CELSIUS | BM53.0$$B71.0 |
| TEMP RISE RATING IN DEG CELSIUS FOR CONTINUOUS OPERATION | 71.0 |
| WINTERIZATION FEATURE | INCLUDED |
| HOUSING TYPE | INCLOSED |
| PRIME MOVER STARTING METHOD | C ANY ACCEPTABLE |
| AUTOMATIC STARTING FEATURE | NOT PROVIDED |
| RADIO INTERFERENCE SUPPRESSION | INCLUDED |
| AC WATTAGE RATING | 15.0 KILOWATTS |
| FREQUENCY RATING | 400.0 HERTZ NOMINAL |
| PHASE | SINGLE |
| LINE TO LINE VOLTAGE IN VOLTS | 115.0 |
| POWER FACTOR IN PERCENT | 0.8 |
| DC VOLTAGE RATING | 28.0 VOLTS NOMINAL |
| DC WATTAGE RATING | 45.0 KILOWATTS |
| EXCITOR TYPE | SELF-EXCITED |
| EXCITOR | NOT INCLUDED |
| MANUFACTURER NAME | ECLIPSE-PIONEER CORP;JACK AND HEINTZ INC |
| IDENTIFYING NUMBER | 28E03-1A TYPE NO. AND G-23-3 TYPE NO. |
| CRANKING VOLTAGE IN VOLTS | 24.0 |
| PRIME MOVER MANUFACTURER NAME | CONTINENTAL ELECTRIC CO |
| DOCUMENT CONTROLLING AGENCY | USAF |
| DOCUMENT IDENTIFICATION | NO. 35C2-3-26-1 AND -3 AND -4 |
| INCLOSURE TYPE | FULLY INCLOSED |