Part Details | ELECTRICAL FUEL CELL
6116-01-239-6577 A basic item (reaction chamber) designed to produce an electromotive force (current) directly and continuously from an oxidation-reduction type of chemical reaction when two or more chemicals (fuel and oxidizer) are supplied. For items of this type which include tanks, pumps, controls, and the like, see POWER UNIT, FUEL CELL.
Alternate Parts: CLASS B3 OXYGEN CELL, CLASS B-3 OXYGEN CELL, 6116-01-239-6577, 01-239-6577, 6116012396577, 012396577
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
61 | SEP 01, 1986 | 01-239-6577 | 61836 ( FUEL CELL, ELECTRICAL ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6116-01-239-6577
Part Number | Cage Code | Manufacturer |
---|---|---|
CLASS B-3 OXYGEN CELL | 21070 | TELEDYNE INSTRUMENTS, INC.DBA TELEDYNE ANALYTICAL INSTRUMENTS |
Technical Data | NSN 6116-01-239-6577
Characteristic | Specifications |
---|---|
GENERAL CHARACTERISTICS ITEM DESCRIPTION | WARRANTED FOR 12 MONTHS CONTINUOUS USE IN AIR; OPERATES IN ANY HUMIDITY FROM 0 TO 100 PCT; AUTOMATICALLY TEMPERATURE COMPENSATED FROM 32.0 TO 122.0 DEG F; ELECTROCHEMICAL TRANSDUCER; SENSES THE PRESENCE OF OXYGEN IN ANY ATMOSPHERE AND IN ANY COMBINATION OF GAS MIXTURES; DISPOSABLE; NOT AFFECTED BY SHOCK VIBRATION OR POSITION; COMPLETELY MAINTENANCE FREE; EXTREMELY STABLE OUTPUT; 2 TO 4 WEEK CALIBRATION CHECK RECOMMENDED; SHELF LIFE 1 TO 3 YEARS; 90 PCT RESPONSE TIME IN 13 SEC; 1.250 IN DIA; 0.750 IN THICK; LARGE SENSING AREA |