Part Details | POWER TRANSFORMER
6120-01-589-9539 A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). It may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. Also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. For transformers having winding(s) common to both input and output circuits, see TRANSFORMER (1), POWER, AUTOTRANSFORMER. Excludes TRANSFORMER (1), PULSE.
Alternate Parts: VPS230350, VPS230-350, KN003062, 6120-01-589-9539, 01-589-9539, 6120015899539, 015899539
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
61 | NOV 09, 2010 | 01-589-9539 | 32496 ( TRANSFORMER, POWER ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6120-01-589-9539
Part Number | Cage Code | Manufacturer |
---|---|---|
VPS230-350 | 3FRZ0 | ACUMEN ELECTRONICS INCDIV TRIAD MAGNETICS |
KN003062 | 34228 | L3 TECHNOLOGIES, INC.DBA L3 KEO |
Technical Data | NSN 6120-01-589-9539
Characteristic | Specifications |
---|---|
TERMINAL TYPE AND QUANTITY | 12 SOLDERLESS LUG |
BODY HEIGHT | 3.000 INCHES NOMINAL |
BODY WIDTH | 2.312 INCHES NOMINAL |
OVERALL HEIGHT | 3.000 INCHES NOMINAL |
SPECIAL FEATURES | ELECTRICAL SPECIFICATIONS (@25C); MAX POWER IS 80.0VA; SECONDARY SERIES IS 230.0V CT@0.35A; PARALLEL IS 115.0V@0.7A; VOLTAGE REGULATION IS 25% TYP @ FULL LOAD TO NO LOAD; TEMPERATURE RISE IS 30 C TYP (45C MAX ALLOWED); INSULATION RESISTANCE IS 100 M |
PART NAME ASSIGNED BY CONTROLLING AGENCY | POWER TRANSFORMER, CHASIS MOUNT, QUICK-CONNECT WORLD SERIES |