NSN 6145-01-343-1828

Part Details | ELECTRICAL POWER CABLE

6145-01-343-1828 Two or more insulated conductors (solid or stranded) contained in a common covering, or two or more insulated conductors twisted or molded together without a common covering, or one insulated conductor with a metallic covering, covering, shield, or outer conductor. The rated working voltage of the item must be 300 volts or more, or in lieu of this the test voltage must be 1,000 volts or more; and the size of each individual conductor must be number 18 American Wire Gage (0.75 SQUARE MILLIMETERS) or larger. For cables with uninsulated neutral conductor use the hightest rated voltage. Refers to bulk quantities only, for items of definite length with processed ends or terminated in fittings, see CABLE ASSEMBLY, POWER, ELECTRICAL. For low voltage aircraft and automotive cable, see CABLE, SPECIAL PURPOSE, ELECTRICAL.

Alternate Parts: 02722, 02722, 78189102722, 78-1891-02722, 6145-01-343-1828, 01-343-1828, 6145013431828, 013431828

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
61AUG 07, 199101-343-182800232 ( CABLE, POWER, ELECTRICAL )
REFERENCE DRAWINGS & PICTURES

ROUND

Cross Reference | NSN 6145-01-343-1828
Part Number Cage Code Manufacturer
0272281774GENERAL CABLE CORPORATIONDBA GENERAL CABLE
0272207759MANATEE, COUNTY OF
78-1891-027223X968WESTINGHOUSE ELECTRIC SUPPLY CO
Technical Data | NSN 6145-01-343-1828
Characteristic Specifications
CONDUCTOR QUANTITY2
CONDUCTOR ARRANGEMENT AND QUANTITY2 SINGLES
CROSS-SECTIONAL SHAPE STYLE ROUND
CROSS SECTION OUTSIDE DIAMETER0.370 INCHES NOMINAL
TEMP RATING-40.0 DEG CELSIUS AND 90.0 DEG CELSIUS
SPECIAL FEATURESMEETS UL TYPES SOW-A AND SO