NSN 6150-01-432-9017

Part Details | ELECTRICAL LOAD BANK

6150-01-432-9017 A set (bank) of electrical elements that are passive (resistive, inductive, capacitive) or active (motors, batteries). They are usually located adjacent to each other to form a consolidated set of any of these elements or any combination of them. A load bank is used to replace distributed or dispersed load elements contained in a power distribution system or electrical network for the purpose of providing a concentrated load. A load bank contains all the essential electrical characteristics necessary to terminate the circuit and functions in the same manner as the load which it is intended to replace. This description necessarily includes a bank of light bulbs or cone heating elements where energy conversion is primarily in the form of heat although visible radiant energy is the natural result of incandescent heating. Load banks are intended to cover a specific range of characteristics and normally operate at DC or at power frequencies 50, 60, or 400 Hz AC. Load banks may be uninstrumented or complete with integral instrumention and may also be furnished as skid or trailer mounted. Excludes TEST SET, ELECTRICAL (as modified). See also DUMMY LOAD, ELECTRICAL.

Alternate Parts: 1107017, 6150-01-432-9017, 01-432-9017, 6150014329017, 014329017

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
61JUN 17, 199601-432-901733776 ( LOAD BANK, ELECTRICAL )
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6150-01-432-9017
Part Number Cage Code Manufacturer
110701724862N H RESEARCH, INCORPORATED
Technical Data | NSN 6150-01-432-9017
Characteristic Specifications
TEST TYPE FOR WHICH DESIGNEDPROGRAMMABLE DYNAMIC ISOLATED DC LOAD MODULES
OPERATING TEST CAPABILITYLOAD SET, 8 EACH, 10VDC TO 400VDC600 WATTS, 0 TO 60 AMPS
ELECTRICAL POWER SOURCE RELATIONSHIP SELF-CONTAINED
AC VOLTAGE RATINGB103.0 VOLTS AND C129.0 VOLTS
FREQUENCY RATINGB47.0 HERTZ AND C63.0 HERTZ
PHASE SINGLE
DC VOLTAGE RATINGB10.0 VOLTS AND C400.0 VOLTS
INCLOSURE FEATURE SINGLE ITEM W/HOUSING
DEPTH26.250 INCHES NOMINAL
HEIGHT10.500 INCHES NOMINAL
WIDTH19.000 INCHES NOMINAL
SPECIAL FEATURESDWG TITLE: PROGRAMMABLE LOAD, CONTROLLABLE VIA IEEE-488 BUS USING HIGH LEVEL; BUILT-IN SELF TEST; CONTAINS 1 LOAD CONTROLLER AND 8, 600 WATT, 60 AMP, 10-400VDC ELECTRONIC LOADS
END ITEM IDENTIFICATIONPOWER SUPPLY TEST STATION NSN 6625013991759