Part Details | FIRE DETECTOR SYSTEM SENSING ELEMENT
6340-00-707-7133 An item consisting of a pair of electrical conductors imbedded in a semiconductor material, having a negative temperature coefficient of resistance which is tightly encased in a suitable metallic tube. The ends of the assembly are terminated for adaption in a fire detector system.
Alternate Parts: 356200400, 35620-0-400, 6340-00-707-7133, 00-707-7133, 6340007077133, 007077133
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
63 | JAN 01, 1963 | 00-707-7133 | 20919 ( SENSING ELEMENT, FIRE DETECTOR SYSTEM ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6340-00-707-7133
Part Number | Cage Code | Manufacturer |
---|---|---|
35620-0-400 | 73168 | KIDDE TECHNOLOGIES INC.DBA FENWAL SAFETY SYSTEMS |
Technical Data | NSN 6340-00-707-7133
Characteristic | Specifications |
---|---|
ELEMENT LENGTH | 10.000 FEET NOMINAL |
FIRE ALARM MINIMUM TEMP SETTING | 400.0 DEG FAHRENHEIT |
TEMP SETTING TOLERANCE | 20.0 DEG FAHRENHEIT NOMINAL |
TERMINATION QUANTITY | 2 |
TERMINATION CONTROLLING AGENCY | FENWAL,INC |
TERMINATION TYPE | CONNECTOR PLUG |
TERMINATION IDENTIFICATION | TYPE AN3106-12S-3P |
FSC APPLICATION DATA | FIRE EXTINGUISHING SYSTEM ASSEMBLIES,AIRCRAFT |