Part Details | UTILITY RETRACTOR
6515-01-458-7927 An instrument designed to be used during tissue retraction and normal abdominal surgical procedures. Excludes RETRACTOR,ABDOMINAL; RETRACTOR,GENERAL OPERATING; and RETRACTOR,TISSUE.
Alternate Parts: 180971, 18-0971, VMSU3344, SU3344, SK603615, SK60-3615, SU3344, 504212, 50-4212, 981791, 98-1791, 11136, 11-136, 5867603615, 164168, 16-4168, 603615, 60-3615, 164168, 6515-01-458-7927, 01-458-7927, 6515014587927, 014587927
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 65 | SEP 10, 1998 | 01-458-7927 | 47063 ( RETRACTOR, UTILITY ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6515-01-458-7927
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 18-0971 | 054A6 | BOSS INSTRUMENTS, LTD., INC. |
| VMSU3344 | 07TA6 | CARDINAL HEALTH 200, LLC |
| SU3344 | 07TA6 | CARDINAL HEALTH 200, LLC |
| SK60-3615 | 07TA6 | CARDINAL HEALTH 200, LLC |
| SU3344 | 5DKK1 | CAREFUSION 2200, INC |
| 50-4212 | 13372 | CODMAN & SHURTLEFF INC |
| 98-1791 | 89875 | DEFENSE LOGISTICS AGENCYDIRECTORATE OF MEDICAL MATERIEL |
| 11-136 | 07920 | MILTEX INSTRUMENT COMPANY INC |
| 5867603615 | 9C381 | OWENS & MINOR DISTRIBUTION, INC. |
| 16-4168 | 47258 | PILLING SURGICAL INCDBA PILLING WECK DIV PILLING |
| 60-3615 | 55187 | SKLAR CORPORATIONDBA MISDOM FRANK & SKLAR |
| 164168 | 1SL40 | TELEFLEX MEDICAL INCORPORATEDDBA TELEFLEX MEDICAL |
Technical Data | NSN 6515-01-458-7927
| Characteristic | Specifications |
|---|---|
| MATERIAL AND LOCATION | STEEL OVERALL |
| DESIGN FORM | STRAIGHT |
| OVERALL LENGTH | 13.000 INCHES NOMINAL |
| OVERALL WIDTH | 1.500 INCHES NOMINAL |
| SPECIAL FEATURES | MALLEABLE RIBBON RETRACTOR, HAND HELD FOR TISSUE RETRACTION |
| PART NAME ASSIGNED BY CONTROLLING AGENCY | MALLEABLE RETRACTOR MEDIUM |