NSN 6515-01-479-4272

Part Details | DEFIBRILLATOR-MONITOR RECORDER SYSTEM

6515-01-479-4272 A collection of items designed for use in the diagnosis and treatment of patients with cardiac arrest, arrhythmia, and those on an electrocardiograph monitor. May include monitor recorder module, defibrillator module, external paddles, external cable, cassette, electrodes, ruler, stylus, chart paper, and the like. May be mounted to field litter and field bed.

Alternate Parts: 000747, 00-0747, M3860A OPT ABA, M3860A, M3680A WECG, M3680A W/ECG, HEARTSTREAM FR2 AED, 6515-01-479-4272, 01-479-4272, 6515014794272, 014794272

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
65OCT 20, 200001-479-427247731 ( RECORDER SYSTEM, DEFIBRILLATOR-MONITOR )
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6515-01-479-4272
Part Number Cage Code Manufacturer
00-074789875DEFENSE LOGISTICS AGENCYDIRECTORATE OF MEDICAL MATERIEL
M3860A OPT ABA0ZBJ4PHILIPS ELECTRONICS NORTH AMERICACORPORATION
M3860A0ZBJ4PHILIPS ELECTRONICS NORTH AMERICACORPORATION
M3680A W/ECG0ZBJ4PHILIPS ELECTRONICS NORTH AMERICACORPORATION
HEARTSTREAM FR2 AED0ZBJ4PHILIPS ELECTRONICS NORTH AMERICACORPORATION
Technical Data | NSN 6515-01-479-4272
Characteristic Specifications
MODEL NUMBERM3860A, OPT ABA
DISPOSITION AFTER INITIAL USE REUSABLE
SPECIAL FEATURESHEARTSTREAM FR2 AED, INCLUDES ONE USER'S GUIDE, 2 PACK DP2 AND 6 PACK DISPOSABLE, SELF-ADHERING DEFIB PADS W/INTEGRATED CABLE AND CONNECTOR; TRAY FOR DATA CARD, AND A QUICK REFERENCE CARD, UNAMBIGIOUS VOICE COMMANDS AND CLEAR, READABLE TEXT PROMPTS; SIMPLE 1-2-3 LAYOUT GUIDES USERS TO A RAPID RESPONSE;SEMIAUTOMATIC OPERATING MODE; CHARGE TIME FROM SHOCK ADVISED; TYPICALLY LESS THAN 10 SEC; SINGLE ENERGY OUTPUT, EXTENSIVE TEXT PROMPTS AND AUDIBLE MESSAGE GUIDE USER THRU PROTOCOL; 2.6X8.5X8.5 IN., 4.7 LBS WITH 12 VDC 4.2 LIMNO2 DISPOSABLE LONG LIFE BATTERY WITH CAPACITY OF 300 SHOCKS OR 12 HR OP TIME; ELAPSED TIME AND NUMBER OF SHOCKS DELIVERED DISPLAYED ON SCREEN; AUTOMATIC SELF TESTS; AUTOMATIC STAND-BY
SUPPLEMENTARY FEATURESECG: HIGH RESOLUTION LCD SCREEN W/BRIGHT BACKLIGHT; 30 TP 300 BPM HEART RATE UPDATED EACH ANALYSIS PERIOD DURING MONITORING; 1 TO 20 HZ FREQUENCY RESPONSE; ECG SMART ANALYSIS PROVIDES EXCEPTIONAL LEVEL OF ACCURACY; GREATLY REDUCING POSSIBILITY OF INAPPROPRIATE SHOCK DELIVERY; EXCEEDS PERFORMANCE REQUIREMENTS FOR AAMI AND AHA STANDARDS FOR SPECIFICITY AND SENSITIVITY; PROMPTLY DISPAYS ECG ALONG WITH OTHER IMPORTANT INFORMATION SUCH AS HEART RATE; TOTAL SHOCKS DELIVERED; LENGTH OF TIME DEVICE IS IN USE AND ON-SCENE EVENT REVIEW; ALLOWS VIEW OF CURRENT STATUS AND A CHRONOLOGY OF EVENTS FROM THE RESCUE ATTEMPT
PART NAME ASSIGNED BY CONTROLLING AGENCYDEFIBRILLATOR/MONITOR-RECORDER SYSTEM REUSABLE
UNIT PACKAGE QUANTITY1