Part Details | DEFIBRILLATOR-MONITOR RECORDER SYSTEM
6515-01-488-5723 A collection of items designed for use in the diagnosis and treatment of patients with cardiac arrest, arrhythmia, and those on an electrocardiograph monitor. May include monitor recorder module, defibrillator module, external paddles, external cable, cassette, electrodes, ruler, stylus, chart paper, and the like. May be mounted to field litter and field bed.
Alternate Parts: 010397, 01-0397, 6515NCM010318, 40610511100123010, 4-0610-5111-0012-3010, M SERIES, 6515-01-488-5723, 01-488-5723, 6515014885723, 014885723
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 65 | AUG 28, 2001 | 01-488-5723 | 47731 ( RECORDER SYSTEM, DEFIBRILLATOR-MONITOR ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6515-01-488-5723
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 01-0397 | 89875 | DEFENSE LOGISTICS AGENCYDIRECTORATE OF MEDICAL MATERIEL |
| 6515NCM010318 | 64616 | DEFENSE MEDICAL STANDARDIZATIONBOARD |
| 4-0610-5111-0012-3010 | 0UJ27 | ZOLL MEDICAL CORPORATION |
| M SERIES | 0UJ27 | ZOLL MEDICAL CORPORATION |
Technical Data | NSN 6515-01-488-5723
| Characteristic | Specifications |
|---|---|
| FURNISHED ITEMS | M SERIES EXTERNAL PADDLE ASSY APEX/STERNUM W/CONTROLS AND BUILT-IN PEDIATRIC ELECTRODES (8000-1010-01)-1 EACH; EXTREME PACK II CARRY CASE (8000-0656)-1 EACH; RECORDER PAPER 80 MM FAN FOLD (8000-0302)-1 PG; SMART BATTERY COMPLETE (8004-0103-01)-1 EACH; DEP READINESS PACK (8900-4016-01)-1 PG; INSERVICE VIDEO FOR M SERIES (9650-0073)-1 EACH; OPERATOR'S MANUAL-1 EACH |
| DISPOSITION AFTER INITIAL USE | REUSABLE |
| SPECIAL FEATURES | ACLS PLUS-MONOPHASIC, MANUAL/ADVISORY DEFIBRILLATOR W/AC POWER, MULTIPLE APPLICATION PRINTER WITH SUMMARY REPORT, CODE MARKERS, SP02 W/REUSEABLE SENSOR AND 8 FT CABLE AND NONINVASIVE PACING; INCLUDES HIGH CONTRAST DISPLAY, 3-LEAD PATIENT CABLE W/INTEGRAL LEAD WIRES, UNIVERSAL CABLE, ONE RECHARGEABLE LEAD ACID BATTERY, AC MAINS POWER CORD, ONE PKG OF RECORDER PAPER, INTEGRAL DIAGNOSTIC FREQUENCY RESPONSE FOR 12-LEAD (REQUIRES 5-LEAD OR 1 STEP PATIENT CABLE), TWO PCMCIA CARD SLOTS, OPERATOR'S MANUAL AND STANDARD FIVE YR WARRANTY FOR HOSPTIAL USE, WITH OPTIONS: ACLS PLUS WITH NIBP W/ADULT-PLUS CUFF AND HOSE, SP02 W/REUSEABLE SENSOR AND 8 FT CABLE AND NONINVASIVE PACING |
| PORTABILITY METHOD | HINGED EXTERNAL HANDLES |
| CONTAINER TYPE | |
| PART NAME ASSIGNED BY CONTROLLING AGENCY | DEFIBRILLATOR/MONITOR-RECORDER SYSTEM |