Part Details | PULSE OXIMETER
6515-01-572-7224 An item designed for use in monitoring oxygen saturation in the blood, pulse rate, saturated oxygen trend, and pulse amplitude. May include visual and audible alarms, preset alarm parameters, alarm silencer, reusable finger probes, and the like.
Alternate Parts: 11075, 6515NCM093210, RAD57 COOXIMETER, RAD57 CO-OXIMETER, 9216, 9062, 6515-01-572-7224, 01-572-7224, 6515015727224, 015727224
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 65 | MAR 23, 2009 | 01-572-7224 | 48302 ( OXIMETER, PULSE ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6515-01-572-7224
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 11075 | 89875 | DEFENSE LOGISTICS AGENCYDIRECTORATE OF MEDICAL MATERIEL |
| 6515NCM093210 | 64616 | DEFENSE MEDICAL STANDARDIZATIONBOARD |
| RAD57 CO-OXIMETER | 3BHG4 | MASIMO CORPORATION |
| 9216 | 3BHG4 | MASIMO CORPORATION |
| 9062 | 3BHG4 | MASIMO CORPORATION |
Technical Data | NSN 6515-01-572-7224
| Characteristic | Specifications |
|---|---|
| PORTABILITY | PORTABLE |
| CARRYING CASE | PROVIDED |
| FURNISHED ITEMS AND QUANTITY | WATER RESISTANT HANDHELD CARRYING CASE, 1EA; RAINBOW DCI-DC3 REUSABLE DIRECT CONNECT SENSOR, 1EA; OPERATOR MANUAL AND TRAINING/INSERVICE, 1EA |
| FEATURES PROVIDED | BATTERY POWERED |
| SPECIAL FEATURES | HANDHELD; RAD-57, CO-OXIMETER, BASE MODEL ONLY; WITH OXYGEN SATURATION (SPO2), PULSE RATE (PR), AND PERFUSION INDEX (PI); DESIGNED FOR CONTINUOUS OR SPOT CHECK APPLICATIONS; USES FOUR AA ALKALINE BATTERIES; DIMENSIONS: 6.2 IN.BY 3.0 IN. BY 1.4 INCHES; HANDHELD WEIGHT: 13OZ. FOR THE MMESO STANDARDIZED JOINT PRODUCT OF CHOICE, USE CAGE 3BHG4 AND PART NUMBER 9216. REPLACEMENT ITEM FOR 6515-01-590-8493, OXIMETER, PULSE, (CANCELLED NIIN). |
| UNIVERSAL MEDICAL DEVICE NOMENCLATURE SYSTEM CODE | 17148 |
| SUPPLEMENTARY FEATURES | RUGGED AND LIGHTWEIGHT, IDEAL FOR ANY FIELD OR HOSPITAL SETTING; BASE MODEL CAN BE UPGRADED AT ADDITIONAL COST, TO INCLUDE THE FOLLOWING SUPPORT ITEM: 6515-01-590-8564, 6515-01-590-8577, 6515-01-590-8571, 6515-01-590-8607, 6515-01-590-8613, 6515-01-590-8579, 6515-01-590-8876, 6515-01-590-8894, 6515-01-8850, 6515-01-590-8859, 6515-01-590-8882, 6515-01-590-8895, 6515-01-590-8896, 6515-01-590-8899, 6515-01-590-8905, 6515-01-590-8864, AND 6515-01-590-8594. |
| PART NAME ASSIGNED BY CONTROLLING AGENCY | OXIMETER RAD-57 CO-OXIMETER MASIMO SET HANDHELD, BASE MODEL ONLY, W/OXYGEN SATURATION (SPO2), PULSE RATE (PR) AND PERFUSION INDEX (PI) |