Part Details | RADIOGRAPHIC AND FLUOROSCOPIC X-RAY APPARATUS
6525-00-853-8121
Alternate Parts: FEDGGX00635, 6525-00-853-8121, 00-853-8121, 6525008538121, 008538121
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
65 | JAN 01, 1962 | 00-853-8121 | 06321 ( X-RAY APPARATUS, RADIOGRAPHIC AND FLUOROSCOPIC ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6525-00-853-8121
Part Number | Cage Code | Manufacturer |
---|---|---|
FEDGGX00635 | 81348 | FEDERAL SPECIFICATIONSPROMULGATED BY GENERAL SERVICES |
Technical Data | NSN 6525-00-853-8121
Characteristic | Specifications |
---|---|
DESIGN TYPE | LX ANY ACCEPTABLE |
TUBE TYPE | DOUBLE FOCUS, ROTATING ANODE RADIOGRAPHIC AND DOUBLE FOCUS, ROTATING ANODE FLUOROSCOPIC |
TUBE QUANTITY | A1$$A1 |
TUBE COOLING METHOD | AIR AND AIR |
TUBE MOUNTING TYPE | TUBE STAND AND RD ANY ACCEPTABLE |
TUBE STAND MOUNTING TYPE | OVERHEAD |
TABLE TYPE | TILTING |
TILT RANGE | 90 DEG TRENDELENBURG TO VERTICAL |
DRIVE TYPE | MOTOR |
BUCKY DIAPHRAGM | INCLUDED |
CONTROL TYPE | VERTICAL |
MOUNTING TYPE | STATIONARY |
OPERATION METHOD | AUTOMATIC |
RADIOGRAPHIC TIMER TYPE | EXPOSURE |
FLUOROSCOPIC TIMER TYPE | SYNCHRONOUS MOTOR |
TRANSFORMER RECTIFICATION METHOD | ELECTRON TUBE |
RECTIFICATION TYPE | FULL-WAVE |
TRANSFORMER OUTPUT CAPACITY | 500 MA AT 125 KV PEAK,300 MA AT 150 KV PEAK |
FLUOROSCOPIC SCREEN TYPE | ANY ACCEPTABLE |
SCREEN LENGTH | 12.000 INCHES NOMINAL |
SCREEN WIDTH | 12.000 INCHES NOMINAL |
SCREEN TYPE | W/SPOT-FILM |
CASSETTE SIZE | 8 IN. BY 10 IN. |
VOLTAGE IN VOLTS | B190.0$$B250.0 |
FREQUENCY IN HERTZ | 60.0 |
PHASE | SINGLE |
ELECTRIC POWER RATING | 65000.0 WATTS NOMINAL |
ACCESSORY COMPONENTS AND QUANTITY | PHOTO-TIMING CIRCUIT 1,COMPRESSION DEVICE 1,MULTIDIAPHRAGM ADJUSTABLE RADIOGRAPHIC CONE 1,CONTROL /SEPARATE KILOVOLTAGE/FOR FLUOROSCOPIC KILOVO LTAGES 1,FOOTREST 1,MILLIAMPERE-SECOND METER 1,SPOT-FILM CHANGE-OVER DEVICE 1,MYLOGRAPHIC SUPPORT PATIENT 1,SHOULDER SUPPORT 1 |
SPECIAL FEATURES | REQUISITION SCHOULD STATE WHETHER HIGH-SPEED INCERTS ARE REQUIRED |
SUPPLEMENTARY FEATURES | REQUISITION SHOULD STATE FLOOR-LOADING CAPACITY,CEILING STRENGTH AND HEIGHT,WALL AND FLOOR CONSTRUCTION (CONCRETE,WOOD,ETC),ELECTRICAL SUPPLY AND CAPACITY,DIAGRAM OF ROOM INDICATING DIMENSIONS,COMPATABILITY W/EXISTING FACILITIES,WHETHER OR NOT CONTRACTOR INSTALLATION SERVICE IS REQUIRED,AND WHETHER HIGH-SPEED INCERTS ARE REQUIRED |
PART NAME ASSIGNED BY CONTROLLING AGENCY | X-RAY APPARATUS RADIOGR-FLUOROSCOPIC 500MA 150PKV 230V 60HZ AC |