Part Details | FAULT LOCATING INDICATOR
6625-00-353-0719 An electrically activated item specifically designed to indicate the occurrence of a malfunction in a component of an electronic set, central or system. It may indicate the malfunction by a pop-out button (e.g. ground fault interrupt outlets) or color change by emitted light or displayed in a window. The indicator may utilize a "push to test" button. It does not make quantitative or qualitative tests such a provided by test sets.
Alternate Parts: 43300121, 4330012-1, M157DA28WBLKS429A, M157DA-28-W/BLK-S429A, MI57D28WBLKS429, MI57D-28-W/BLK-S429, 43300121, 4330012-1, 43300021, 4330002-1, MI57D28WBLKS429, MI57D-28W/BLK-S429, B21606, 6625-00-353-0719, 00-353-0719, 6625003530719, 003530719
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 66 | FEB 02, 1974 | 00-353-0719 | 60639 ( INDICATOR, FAULT LOCATING ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6625-00-353-0719
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 4330012-1 | 76301 | BOEING COMPANY, THEDBA BOEING |
| M157DA-28-W/BLK-S429A | 10236 | ELECTRODYNAMICS, INC.DBA L-3 COMMUNICATIONS |
| MI57D-28-W/BLK-S429 | 10236 | ELECTRODYNAMICS, INC.DBA L-3 COMMUNICATIONS |
| 4330012-1 | 19133 | MCDONNELL DOUGLAS CORPMCDONNELL DOUGLAS AEROSPACE |
| 4330002-1 | 19133 | MCDONNELL DOUGLAS CORPMCDONNELL DOUGLAS AEROSPACE |
| MI57D-28W/BLK-S429 | 07479 | MINELCO INCSUB OF TALLEY INDUSTRIES INC |
| B21606 | 82227 | VDO CONTROL SYSTEMS INC |
Technical Data | NSN 6625-00-353-0719
| Characteristic | Specifications |
|---|---|
| CASE MATERIAL | ALUMINUM |
| ELECTRICAL CONNECTION QUANTITY | 4 |
| PRESENTATION TYPE | WINDOW |
| CURRENT TYPE | DC |
| DC VOLTAGE RATING | 28.0 VOLTS NOMINAL |
| COIL DC RESISTANCE | 800.0 OHMS NOMINAL |
| CONTACT QUANTITY | 4 |
| CONTACT TYPE | WIRE LEAD |
| MOUNTING FACILITY TYPE AND QUANTITY | 1 THREADED CASE |
| LENGTH | 1.000 INCHES NOMINAL |
| DIAMETER | 0.593 INCHES NOMINAL |
| FEATURES PROVIDED | COIL AND MOUNTING HARDWARE |
| SPECIAL FEATURES | WHITE FAULT INDICATION ELEC RESET TO BLACK |