6625-00-391-7956 A test set primarily designed to detect and indicate insulation breakdown in electric motors, transformers, and the like, at specific test voltages. See also TEST SET, ARMATURE; and OHMMETER.
Alternate Parts: 41, 6625-00-391-7956, 00-391-7956, 6625003917956, 003917956
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 66 | JAN 01, 1963 | 00-391-7956 | 16408 ( TEST SET, INSULATION BREAKDOWN ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6625-00-391-7956
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 41 | 59073 | TAKK INDUSTRIES INC |
Technical Data | NSN 6625-00-391-7956
| Characteristic | Specifications |
|---|---|
| OUTPUT CURRENT TYPE | DC |
| OUTPUT VOLTAGE RATING | 2.000 KILOVOLTS MINIMUM AND 15.000 KILOVOLTS MAXIMUM |
| INSTALLATION DESIGN | PORTABLE |
| LEAKAGE INDICATOR TYPE | LAMP |
| METER QUANTITY | 1 |
| METER TYPE | AMMETER AND VOLTMETER |
| SCALE RANGE | +0.0 TO +100.0 MICROAMPS AND +0.0 TO +15.0 KILOVOLTS |
| TEST LEAD QUANTITY | 2 |
| WIRE LEAD LENGTH | 72.000 INCHES NOMINAL |
| WIRE TERMINATION TYPE | CLIP |
| AC VOLTAGE RATING | 110.0 VOLTS NOMINAL |
| FREQUENCY RATING | 60.000 HERTZ NOMINAL |
| PHASE | SINGLE |
| OVERALL LENGTH | 18.000 INCHES NOMINAL |
| OVERALL WIDTH | 11.500 INCHES NOMINAL |
| OVERALL HEIGHT | 9.500 INCHES NOMINAL |
| CIRCUIT OVERLOAD PROTECTION DEVICE | FUSE |