NSN 6625-00-438-9086

Part Details | PULSE GENERATOR

6625-00-438-9086 An electronic device which develops a discontinuous electrical potential with an abrupt rate of change of voltage which determines the harmonic content of the pulse train. The duration of a single pulse output is relatively short compared to the time of the recurrence cycle. See also GENERATOR, SINGLE PULSE; and GENERATOR, ELECTRONIC MARKER.

Alternate Parts: 650TY5, 6625-00-438-9086, 00-438-9086, 6625004389086, 004389086

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
66NOV 26, 196900-438-908600411 ( GENERATOR, PULSE )
REFERENCE DRAWINGS & PICTURES

RECTANGULAR OR SQUARE

Cross Reference | NSN 6625-00-438-9086
Part Number Cage Code Manufacturer
650TY514814ELDORADO ELECTRODATA CORP
Technical Data | NSN 6625-00-438-9086
Characteristic Specifications
CIRCUIT CONSTRUCTION TYPE SOLID STATE
SIGNAL DATA TYPE PER CHANNEL OUTPUT CHANNEL PULSE DELAY
OUTPUT WAVE SHAPE PULSE, VARIABLE WIDTH
AVERAGE LIFE MEASUREMENT NOT RATED
MAXIMUM OPERATING ALTITUDE RATING10000.0 FEET
OPERATING TEMP RANGE+0.0 TO +52.0 DEG FAHRENHEIT
EXTERNAL AC OPERATING VOLTAGE IN VOLTS115.0 NOMINAL SINGLE VOLTAGE AND 230.0 NOMINAL SINGLE VOLTAGE
OPERATING AC FREQUENCY IN HERTZ48.0 MINIMUM SINGLE VOLTAGE AND 62.0 MAXIMUM SINGLE VOLTAGE
INCLOSURE TYPE ENCASED
INSTALLATION DESIGN RACK
BASIC SHAPE STYLE RECTANGULAR OR SQUARE
OVERALL LENGTH17.500 INCHES NOMINAL
OVERALL HEIGHT5.250 INCHES NOMINAL
OVERALL WIDTH16.750 INCHES NOMINAL
SPECIAL FEATURESMANUFACTURERS NAME: GENERATOR, DIGITAL DELAY
SUPPLEMENTARY FEATURESACCESSORIES SUPPLIED ONE 3-TO-2 WIRE AC LINE ADAPTER TWO MOUNTING EARS,ONE EXTENDER BOARD,TWO INSTRUCTION MANUALS; OPTIONS T=115/230VAC 50-400HZ,Y5=9 DIGIT RANGE 999,999,999 NANOSECONDS
FUNCTIONAL CLASSIFICATIONBB-1.5
FUNCTIONAL DESCRIPTIONGENERATES ACCURATE DELAYS IN ONE NANOSECOND STEPS OVER A WIDE RANGE; DELAY TIME READILY DIALED IN WITH THUMB WHEEL SWITCHES; ALL INPUT AND OUTPUT SIGNAL POLARITIES ARE SELECTABLE; INPUT TRIGGER SENSITIVITY VARIABLE BY FRONT PANEL CONTROL; 3 INPUT TRIGGERING MODES ARE PROVIDED: EXTERNAL, MANUAL AND INTERNAL