Part Details | SPECTRUM ANALYZER
6625-00-444-4071 An instrument specifically designed to measure the amplitude and frequency of the constituents of a complex electrical wave form. May include transducer mechanism for converting sound pressure into electrical energy.
Alternate Parts: 3710AOPT00400801537163702B370, 3710AOPT004008015/3716/3702B/370, 3710AE20, 3710A-E20, 3710AE20, 3710A-E20, 6625-00-444-4071, 00-444-4071, 6625004444071, 004444071
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 66 | DEC 18, 1970 | 00-444-4071 | 00833 ( ANALYZER, SPECTRUM ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6625-00-444-4071
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 3710AOPT004008015/3716/3702B/370 | 28480 | HEWLETT-PACKARD COMPANYDBA HP |
| 3710A-E20 | 28480 | HEWLETT-PACKARD COMPANYDBA HP |
| 3710A-E20 | 1LQK8 | KEYSIGHT TECHNOLOGIES, INC. |
Technical Data | NSN 6625-00-444-4071
| Characteristic | Specifications |
|---|---|
| UNIT TYPE | STANDARD |
| FREQUENCY RANGE RATING | +45.000 TO +95.000 MEGAHERTZ AND +83.300 TO +8200.000 KILOHERTZ |
| SPECIAL FEATURES | C/O HP MODEL 3710A W/OPTIONS 004,008,015 W/PLUG-IN 3716, AND 3702B W/PLUG-IN 3706A AND 15550A ACCESSORY KIT |
| SUPPLEMENTARY FEATURES | CHANGED NAME FROM TEST SET,TELECOMMUNICATION SYSTEM;MFR NAME IS MICROWAVE LINK ANALYZER |
| FUNCTIONAL DESCRIPTION | IDENTIFIES,MEASURES,LOCALIZES DISTORTIONS OCCURRING IN A LINK IN BB/IF DEVICES |