Part Details | FLUXMETER
6625-00-519-2407 An electrical instrument which measures magnetic flux. With appropriate calibration it can be used for measurement of the intensity of a magnetic field. See also METER, FIELD STRENGTH.
Alternate Parts: TS15CAP, TS15CAP, 6625-00-519-2407, 00-519-2407, 6625005192407, 005192407
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 66 | JAN 01, 1961 | 00-519-2407 | 20901 ( FLUXMETER ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6625-00-519-2407
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| TS15CAP | 80058 | JOINT ELECTRONICS TYPE DESIGNATIONSYSTEM |
| TS15CAP | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
Technical Data | NSN 6625-00-519-2407
| Characteristic | Specifications |
|---|---|
| FLUX DENSITY | 1200.0 GAUSS MINIMUM AND 9600.0 GAUSS MAXIMUM |
| SCALE DIRECTION AND RANGE | +12.0 TO +96.0 CLOCKWISE |
| SCALE LINEARITY | NONLINEAR |
| MAGNET GAP RANGE ACCOMMODATED | +0.600 TO +1.500 INCHES |
| MAGNET DIAMETER RANGE ACCOMMODATED | +0.875 TO +2.000 INCHES |
| PROBE HANDLE | INCLUDED |
| MAGNET YOKE QUANTITY | 2 |
| CURRENT TYPE | DC |
| VOLTAGE RATING | 0.2 VOLTS NOMINAL |
| INTERNAL BATTERY ACCOMMODATION | INCLUDED |
| CASE MATERIAL | METAL |