NSN 6625-00-580-1025

Part Details | WATTMETER

6625-00-580-1025 An instrument which measures one or more different electrical power quantities (such as decibels and watts), and is calibrated using watts. The power measurement and/or calibration may be displayed in multiples and/or submultiples thereof on a dial and/or digital readout display. For items designed to measure radio frequency power see TEST SET, ELECTRICAL POWER and METER, MULTIPLE SCALE. Excludes: AMMETER; FREQUENCY METER; MULTIMETER; VOLTMETER.

Alternate Parts: 7040890P2, 7040890P2, HS37040890P2, HS3-7040890P2, 1531, 6625-00-580-1025, 00-580-1025, 6625005801025, 005801025

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
66JAN 01, 196300-580-102528455 ( WATTMETER )
REFERENCE DRAWINGS & PICTURES

THREE HOLE/STUD BOLT CIRCLE

ROUND FLUSH MTG

Cross Reference | NSN 6625-00-580-1025
Part Number Cage Code Manufacturer
7040890P224454GENERAL ELECTRIC COELECTRONIC COMPONENTS DIVISION OF
7040890P224446GENERAL ELECTRIC COMPANY
HS3-7040890P233005JEWELL INSTRUMENTS, LLCDBA MODUTEC
153165092SOLARTRON ELECTRONICS INCWESTON INSTRUMENTS DIV
Technical Data | NSN 6625-00-580-1025
Characteristic Specifications
INSTALLATION DESIGN PANEL
INDICATOR TYPE DIAL W/POINTER
MOVEMENT TYPE MOVING COIL, PERMANENT MAGNET
MOVEMENT SUSPENSION METHOD JEWEL PIVOT BASE
CIRCUIT ATTACHMENT METHOD AND QUANTITY2 SOLDER LUG
POWER SOURCE EXTERNAL
CIRCUIT CURRENT FOR WHICH DESIGNED DC
OPERATING VOLTAGE RATING IN VOLTS0.00015 DC NOMINAL
STYLE DESIGNATOR ROUND FLUSH MTG
METER BODY DIAMETER BEHIND MOUNTING FLANGE2.800 INCHES NOMINAL
METER DEPTH BEHIND MOUNTING FLANGE1.405 INCHES MAXIMUM
OVERALL DIAMETER3.500 INCHES NOMINAL
MOUNTING FACILITY TYPE AND QUANTITY3 UNTHREADED HOLE
MOUNTING HOLE DIAMETER0.150 INCHES NOMINAL
MOUNTING ARRANGEMENT STYLE THREE HOLE/STUD BOLT CIRCLE
MOUNTING BOLT CIRCLE DIAMETER3.160 INCHES NOMINAL
MATERIAL STEEL
NUCLEAR HARDNESS CRITICAL FEATURE NONHARDENED
FURNISHED ITEMS AND QUANTITYNUT 3
FEATURES PROVIDED ZERO ADJUSTER
SPECIAL FEATURESRUGGEDIZED
FSC APPLICATION DATATEST SET,ELECT. EQUIP.