Part Details | AMMETER
6625-00-729-6902 An instrument which measures electric current and is calibrated and marked in amperes or any multiple and/or submultiple thereof. The value may be expressed by means of a pointer and calibrated dial or a digital readout display. For current detecting type of devices, see GALVANOMETER.
Alternate Parts: 409C565A08, S1160073, 409C565A08, S1160073, RX371, RX37, 409C565A08, 6625-00-729-6902, 00-729-6902, 6625007296902, 007296902
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 66 | JAN 01, 1963 | 00-729-6902 | 16450 ( AMMETER ) |
REFERENCE DRAWINGS & PICTURES
FOUR HOLE/STUD RECTANGULAR/SQUARE
RECTANGULAR FLUSH MTG
Cross Reference | NSN 6625-00-729-6902
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 409C565A08 | 6Z382 | HUGHES CORPORATIONDBA WESCHLER INSTRUMENTS |
| S1160073 | 97942 | NORTHROP GRUMMAN SYSTEMS CORPORATIONDIV NORTHROP GRUMMAN SYSTEMS |
| 409C565A08 | 79500 | WESTINGHOUSE ELECTRIC CORP |
| S1160073 | 79500 | WESTINGHOUSE ELECTRIC CORP |
| RX371 | 79500 | WESTINGHOUSE ELECTRIC CORP |
| RX37 | 79500 | WESTINGHOUSE ELECTRIC CORP |
| 409C565A08 | 11660 | WESTINGHOUSE ELECTRIC CORPCONTROL BUSINESS UNIT |
Technical Data | NSN 6625-00-729-6902
| Characteristic | Specifications |
|---|---|
| INSTALLATION DESIGN | PANEL |
| MOVEMENT TYPE | MOVING COIL, PERMANENT MAGNET |
| MOVEMENT SUSPENSION METHOD | JEWEL PIVOT BASE |
| CIRCUIT ATTACHMENT METHOD AND QUANTITY | 2 THREADED STUD |
| SENSITIVITY RATING | 50.0 MILLIVOLTS |
| CIRCUIT CURRENT FOR WHICH DESIGNED | DC |
| STYLE DESIGNATOR | RECTANGULAR FLUSH MTG |
| METER BODY DIAMETER BEHIND MOUNTING FLANGE | 3.813 INCHES NOMINAL |
| METER DEPTH BEHIND MOUNTING FLANGE | 1.625 INCHES NOMINAL |
| OVERALL HEIGHT | 4.219 INCHES NOMINAL |
| OVERALL LENGTH | 1.275 INCHES NOMINAL |
| OVERALL WIDTH | 3.969 INCHES NOMINAL |
| MOUNTING FACILITY TYPE AND QUANTITY | 4 THREADED STUD |
| MOUNTING STUD DIAMETER | 0.125 INCHES NOMINAL |
| MOUNTING ARRANGEMENT STYLE | FOUR HOLE/STUD RECTANGULAR/SQUARE |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 3.000 INCHES NOMINAL |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 3.000 INCHES NOMINAL |
| PANEL FOR WHICH DESIGNED | MAGNETIC |
| MATERIAL | PLASTIC |
| NUCLEAR HARDNESS CRITICAL FEATURE | NONHARDENED |