Part Details | VOLTMETER
6625-00-878-8149 An instrument which measures electrical potential and is calibrated in volts or any multiple and/or submultiple thereof. The value may be expressed by means of a pointer and calibrated dial or a digital readout display.
Alternate Parts: AFX3MN40146, 47012787, 47-012787, B6281, B-6281, 6625-00-878-8149, 00-878-8149, 6625008788149, 008788149
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 66 | JAN 01, 1962 | 00-878-8149 | 16449 ( VOLTMETER ) |
REFERENCE DRAWINGS & PICTURES
SIX HOLE/STUD BOLT CIRCLE
ROUND FLUSH MTG
Cross Reference | NSN 6625-00-878-8149
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| AFX3MN40146 | 33005 | JEWELL INSTRUMENTS, LLCDBA MODUTEC |
| 47-012787 | 77221 | PHAOSTRON INSTRUMENT AND ELECTRONICCOMPANY |
| B-6281 | 96787 | STEWART AVIONICS INC |
Technical Data | NSN 6625-00-878-8149
| Characteristic | Specifications |
|---|---|
| INSTALLATION DESIGN | PANEL |
| INDICATOR TYPE | DIAL W/POINTER |
| MOVEMENT TYPE | MOVING COIL, PERMANENT MAGNET |
| MOVEMENT SUSPENSION METHOD | JEWEL PIVOT BASE |
| CIRCUIT ATTACHMENT METHOD AND QUANTITY | 2 SOLDER STUD |
| POWER SOURCE | EXTERNAL |
| CIRCUIT CURRENT FOR WHICH DESIGNED | AC |
| STYLE DESIGNATOR | ROUND FLUSH MTG |
| METER BODY DIAMETER BEHIND MOUNTING FLANGE | 3.750 INCHES NOMINAL |
| METER DEPTH BEHIND MOUNTING FLANGE | 1.500 INCHES NOMINAL |
| OVERALL DIAMETER | 4.500 INCHES NOMINAL |
| OVERALL LENGTH | 2.275 INCHES NOMINAL |
| MOUNTING FACILITY TYPE AND QUANTITY | 6 UNTHREADED HOLE |
| MOUNTING HOLE DIAMETER | 0.150 INCHES NOMINAL |
| MOUNTING ARRANGEMENT STYLE | SIX HOLE/STUD BOLT CIRCLE |
| MOUNTING BOLT CIRCLE DIAMETER | 4.125 INCHES NOMINAL |
| MATERIAL | ALUMINUM |
| NUCLEAR HARDNESS CRITICAL FEATURE | NONHARDENED |
| FEATURES PROVIDED | MAGNETIC SHIELD |
| SPECIAL FEATURES | CRITICAL APPLICATION: SUPPORT EQUIP. FOR H-3,H-53,H-1 AND H-60 HELICOPTERS AND FOR B-52,F-4,F-15,A-7,A-10,CV-10A,C-5,C-141,T-37,F-16,F-106 AND F-111 ACFT; HERCULES C-130,F-111 AND GALAXY C-5 ACFT |
| RELIABILITY INDICATOR | NOT ESTABLISHED |
| CRITICALITY CODE JUSTIFICATION | FEAT |
| FSC APPLICATION DATA | TEST SET,ELECT. EQUIP. |