6625-01-469-2797 A table designed for general use in the testing of electrical circuits in the maintenance of instruments and appliances operated by electricity.
Alternate Parts: 2625547G002, 6625-01-469-2797, 01-469-2797, 6625014692797, 014692797
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 66 | NOV 09, 1999 | 01-469-2797 | 13641 ( TABLE, ELECTRICAL TEST AND MAINTENANCE ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6625-01-469-2797
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 2625547G002 | 28527 | HARRIS CORPORATIONDBA ELECTRONIC SYSTEMS, INTEGRATED |
Technical Data | NSN 6625-01-469-2797
| Characteristic | Specifications |
|---|---|
| OVERALL WIDTH | 24.000 INCHES NOMINAL |
| OVERALL LENGTH | 72.000 INCHES NOMINAL |
| OVERALL HEIGHT | 24.000 INCHES NOMINAL |
| SPECIAL FEATURES | COOLING AIR 215 CUBIC FEET PER MINUTE FREE DELIVERY; AIRFLOW SWITCH CONTROL; 115.0 VAC, 400.0 HZ; 3 PHASE; FIXED INSTALLATION BUT MOVABLE ON WHEELS; TEST BENCH PROVIDES COOLING FOR LRU-1 THROUGH LRU-4 AND LRU-10 OF THE AN/ALQ-172; ALSO PROVIDES STROAGE FOR ALL CABLES AND ACCESSORIES REQUIRED FOR TEST OF THESE LRUS |
| SUPPLEMENTARY FEATURES | THIS TEST BENCH HAS A BLOWER MODIFICATION WHICH IS THE ONLY DIFFERENCE BETWEEN THE G001 & G002 THE MODIFICATION ON THE TEST BENCH HAS THE AIR FLOW REVERSED WHICH ALLOWS THE AIR TO BE PULLED INTO AN LRU RATHER THAN PUSHING THE AIR; SEE TCTO 12P3-2ALQ172-533 |
| END ITEM IDENTIFICATION | AN/ALQ-172 |