Part Details | DIGITAL READOUT ELECTRONIC COUNTER
6625-01-485-8899 An instrument used to count the frequency of recurrent electronic events and display the count on the panel of the instrument in numeric form. May also include facilities for a readout printed on tape. May include facilities for a very accurate output which can be used as a secondary transfer standard. It can be used to measure frequency, period, time interval, phase angle, frequency ratio, and for multiple period averaging. See also COUNTER, ELECTRONIC, DIGITAL and INDICATOR, DIGITAL DISPLAY.
Alternate Parts: HP53151A, 53151A, 200625776, 6625-01-485-8899, 01-485-8899, 6625014858899, 014858899
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 66 | JUN 11, 2001 | 01-485-8899 | 26835 ( COUNTER, ELECTRONIC, DIGITAL READOUT ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6625-01-485-8899
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| HP53151A | 28480 | HEWLETT-PACKARD COMPANYDBA HP |
| 53151A | 1LQK8 | KEYSIGHT TECHNOLOGIES, INC. |
| 200625776 | 98752 | WARNER ROBINS AIR LOGISTICS CENTER |
Technical Data | NSN 6625-01-485-8899
| Characteristic | Specifications |
|---|---|
| MEASUREMENT TYPE | FREQUENCY |
| DISPLAY POSITIONED DECIMAL POINT | PROVIDED |
| CURRENT TYPE | B$C AC/DC |
| FREQUENCY RATING | 50.0 MEGAHERTZ MINIMUM AND 26.5 GIGAHERTZ MAXIMUM |
| INTERNAL BATTERY ACCOMMODATION | INCLUDED |
| OVERALL LENGTH | 300.0 MILLIMETERS NOMINAL |
| OVERALL WIDTH | 213.0 MILLIMETERS NOMINAL |
| OVERALL HEIGHT | 88.5 MILLIMETERS NOMINAL |
| SPECIAL FEATURES | BACKLIT LCD DISPLAY ENSURES VISIABILITY IN ALL ENVIRONMENTS AT DISTANCEEXCEEDING 15 FEET; REPLACEABLE BATTERIES PROVIDE AT LEAST 2.5 HRS OF CONTINUOUS OPERATION; OR POWERED BY AN EXTERNAL 11-18 VDC SOURCE; FREQUENCY RANGE 10 HZ TO 125 MHZ NORMAL MODE, 10 HZ TO 50 KHZ LOW PASS FILTER ENABLED CHANNEL1, 50 MHZ TO 26.5 GHZ CHANNEL 2 |
| END ITEM IDENTIFICATION | VERSATILE DIAGNOSTIC AUTOMATIC TEST STATION (VDATS); 4920-01-553-1535,(RF-1) |
| UNPACKAGED UNIT WEIGHT | 4.000 GRAMS |
| SUPPLEMENTARY FEATURES | CONTROLLING AGENCY NOMENCLATURE CW MICROWAVE COUNTER; SENSITIVITY CHANNEL 1 10-30 HZ 40 MV, 30 HZ-125 MHZ 25 MV, CHANNEL 2 50-250 MHZ -20 DBM, 0.25-12.4 GHZ -33 DBM, 12.4-18 GHZ -33 DBM18-20 GHZ -29 DBM, 20-26.5 GHZ -25 DB;MAX INPUT CHANNEL 1 2 VRMS, CHANNEL 2 50 MHZ-2 GHZ +5 DBM, 2-46 GHZ +13 DBM; CONNECTOR CHANNEL 1 BNC FEMALE, CHANNEL 2 SMA APC-3.5 COMPATIBLE FEMALE; RESOLUTION 1 HZ TO 1 MHZ |
| FUNCTIONAL DESCRIPTION | WE MICROWAVE COUNTERWITH AN EXTRAWIDEBAND INPUT THAT COVERS THE RF AND MICROWAVE SPECTRUM FROM 50MHZ TO 26.5 GHZ; MEASURING FREQUENCY AND POWER SIMULTANEOUSLY WITH THIS SAME INPUT |
| REFERENCE DATA AND LITERATURE | T.O.51C3-2-243-3;TECH MANUALS 33A1-10-304-1,33A1-10-304-2 |