Part Details | EDDY CURRENT PROBE
6635-01-310-2521 An item with or without attaching cable designed to detect flaws, cracks and the like on surface or near surface metals. Establishes a magnetic field through the probe coil and locates the resulting magnetic disturbance in the item under test. Used in conjunction with DETECTOR, METAL FLAW, ELECTRONIC. Excludes PROD, TEST.
Alternate Parts: PWA43234, 6635-01-310-2521, 01-310-2521, 6635013102521, 013102521
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 66 | NOV 01, 1989 | 01-310-2521 | 36329 ( PROBE, EDDY CURRENT ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6635-01-310-2521
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| PWA43234 | 77445 | UNITED TECHNOLOGIES CORPORATIONDBA PRATT WHITNEY-SPARE PARTS |
Technical Data | NSN 6635-01-310-2521
| Characteristic | Specifications |
|---|---|
| TIP TERMINATION TYPE | PROBE |
| CONDUCTOR ATTACHMENT METHOD | PATCH CORD |
| OVERALL LENGTH | 3.000 INCHES NOMINAL |
| OVERALL WIDTH | 1.500 INCHES NOMINAL |
| FUNCTIONAL DESCRIPTION | USED TO DETECT CRACKING OF THE FRONT COMPRESSOR HUB WHICH OCCURS ALONG THE RIM SLOT TANG RELIEF RADIUS AND ATTHE RIM SLOT TANG FRONT ACUTE CORNER |