Part Details | EDDY CURRENT PROBE
6635-01-465-3173 An item with or without attaching cable designed to detect flaws, cracks and the like on surface or near surface metals. Establishes a magnetic field through the probe coil and locates the resulting magnetic disturbance in the item under test. Used in conjunction with DETECTOR, METAL FLAW, ELECTRONIC. Excludes PROD, TEST.
Alternate Parts: PWA54474, 6635-01-465-3173, 01-465-3173, 6635014653173, 014653173
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 66 | JUN 01, 1999 | 01-465-3173 | 36329 ( PROBE, EDDY CURRENT ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6635-01-465-3173
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| PWA54474 | 77445 | UNITED TECHNOLOGIES CORPORATIONDBA PRATT WHITNEY-SPARE PARTS |
Technical Data | NSN 6635-01-465-3173
| Characteristic | Specifications |
|---|---|
| TIP TERMINATION TYPE | PROBE |
| CONDUCTOR ATTACHMENT METHOD | PROBE IS USED WITH NDT16 OR NDT25 EDDY CURRENT INSTRUMENT AND CONTACT TEST STAND PWA54300 |
| SPECIAL FEATURES | BROACH SLOT OF THE FIRST AND THIRD COMPRESSOR DISK REQUIRE INSPECTION; THIS PROBE WILL FULFILL THE REQUIREMENT TO INSPECT ZONE F OF THE BROACH SLOT OF THESE DISKS; END ITEM:DETECTOR, METAL FLAW, ELECTRONIC; AIRCRAFT, FREEDOM FIGHTER F-5 |