Part Details | ELECTRONIC METAL FLAW DETECTOR
6635-01-522-5936 A non-destructive electromagnetic device which introduces eddy current in a part(s) to be inspected. Changes in the current flow caused by surface variations in the part are reflected into a nearby coil(s) where they are detected and measured by suitable instrumentation which is provided. See also FLUORESCENT PENETRANT INSPECTION UNIT; MAGNETIC INSPECTION UNIT (as modified); TRANSDUCER, ULTRASONIC TEST; X-RAY APPARATUS, RADIOGRAPHIC, INDUSTRIAL.
Alternate Parts: 500HN0192, 6635-01-522-5936, 01-522-5936, 6635015225936, 015225936
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 66 | AUG 05, 2004 | 01-522-5936 | 60394 ( DETECTOR, METAL FLAW, ELECTRONIC ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6635-01-522-5936
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 500HN0192 | 072E5 | RAYTHEON COMPANYDBA RAYTHEON |
Technical Data | NSN 6635-01-522-5936
| Characteristic | Specifications |
|---|---|
| INSTALLATION DESIGN | PORTABLE |
| USAGE DESIGN | EXTERNAL |
| TEST TYPE | SCLEROSCOPE |
| INDICATOR TYPE | AUDIO TONE AND MICROMETER MEASURING MICROSCOPE |
| INDICATOR READING TYPE | SINGLE |
| INDICATOR DESIGN | ELECTRONIC SIGNAL ALARM |
| CARRYING CASE | PROVIDED |
| ACCESSORY COMPONENTS AND QUANTITY | CABLE ASSY 2; PROBE 2 |
| END ITEM IDENTIFICATION | 9LAU7AXSE |
| PART NAME ASSIGNED BY CONTROLLING AGENCY | LAU-7 MISSLE LAUNCHER EDDY CURRENT INSPECTION KIT |